Pentair 472645 manual MegaTherm Model MT, Sizes 500,000 1,825,000 BTU/h, GAS System, Burner Trays

Page 11

MegaTherm Model MT

Old style AP before April 1999, New style after April 1999

Sizes 500,000 - 1,825,000 BTU/h

Part No.

Description

Model Size

Part No.

Description

Model Size

 

 

 

 

 

 

 

GAS SYSTEM

 

 

L0032800

Orifice, LP Gas, 4001-8000 ft

both

BURNER TRAYS

 

 

L0032700

Orifice, LP Gas, 8001-10000 ft ....

both

See listing in MegaTherm HH, PH, VW, PW and IW for common components.

V0004200

Gas Valve, Manual, 1", Nat

 

 

10525901

Gas Manifold Weldment

 

 

 

LP 1010-1200

both ..

500-715

 

(single inlet)

both ..

500

V0004300

Gas Valve, Manual, 1-1/4", Nat

 

 

10525902

Gas Manifold Weldment

 

 

 

LP 1430-1825

both ..

850-1825

 

(single inlet)

both ..

600

V0004800

Gas Valve, Manual, 3/4", LP

both ..

500-850

10525903

Gas Manifold Weldment

 

 

RV0046600

Valve Gas Auto 1x1 Nat/LP 24V ..

both ..

500-850

 

(single inlet)

both ..

715

RV0046700

Gas Valve, Safety, 1-1/4", On/Off

 

10525904

Gas Manifold Weldment

 

 

 

& 2-Stage, Nat

both ..

1010-1670

 

(single inlet)

both ..

850

V0046800

Gas Valve, Safety, 1-1/2" On/Off

 

 

10525905

Gas Manifold Weldment

 

 

 

& 2-Stage, Nat

both ..

1825

 

(single inlet)

both ..

1010

V0047600

Gas Valve Combo, 1x1 Nat 24V

 

10525906

Gas Manifold Weldment

 

 

RV0051200

Valve Gas Combo 1" 24V Nat

 

 

 

(single inlet)

both ..

1200

 

On/Off & 2-Stage

both ..

500-850

10525907

Gas Manifold Weldment

 

 

RV0051300

Valve Gas Combo 1-1/4" 24V Nat

 

 

(single inlet)

both ..

1430

 

On/Off & 2-Stage

both ..

1010-1430

10525908

Gas Manifold Weldment

 

 

V0051400

Gas Valve, Combination/Operating

 

 

(single inlet)

both ..

1670

 

1-1/2", On/Off & 2-Stage, Nat

both ..

1670-1825

10525909

Gas Manifold Weldment

 

 

V0059600

Gas Valve, Combination/Operating

 

 

(single inlet)

both ..

1825

 

3/4", used on 4-Stage, Nat

both ..

500-715

RL0052300 Burner, Main 10 Pack

both

V0054800

Gas Valve, Combination/Operating

 

10529501

Pilot Bracket/Burner Weldment

 

 

 

1", On/Off & 2-Stage, LP

both ..

500-1200

 

(Johnson)

old

V0054900

Gas Valve, Combination/Operating

 

10529502

Pilot Bracket/Burner Weldment

 

 

 

1-1/4", On/Off & 2-Stage, LP

both ..

1430-1825

 

(Honeywell)

both

V0070800

Gas Valve, Combination/Operating

 

R10529300

Pilot Burner IID, Nat 500-1825

 

 

 

3/4", used on 4-Stage, LP

both ..

500-850

 

Honeywell, 4-Stage

both

W0002100

Pilot Gas Valve, Manual, Nat/LP ..

both ..

all

R20039600

Pilot Burner Assy IID LP

 

 

W0019300

Pilot Valve, Solenoid, Nat/LP

both ..

all

 

Honeywell, 4-Stage

both

W0002000

Pilot Regulator, Nat

both ..

all

10547002

Complete Pilot Assy

 

 

W2000200

Pilot Regulator, LP

both ..

all

 

Standing Pilot, LP

both

 

 

 

 

10547001

Complete Pilot Assy

 

 

Manifold cover plate assembliles, anti rotation brackets and tie down

 

Standing Pilot, Nat

both

brackets - see listing for MegaTherm HH, PH, VW, PW and IW for common

W0035800

Pilot Burner (Honeywell)

 

 

components.

 

 

 

 

Standing Pilot, Nat

both

 

 

 

 

W0034400

Pilot Burner (Honeywell)

 

 

ELECTRICAL COMPONENTS

 

 

 

Standing Pilot, LP

both

RE0100900

Controller, Ignition Module

 

 

RW0034300 Pilot Burner (Honeywell) Spark Ignition

 

 

(used prior to April 1999)

both

 

Nat

both

RE2033900

Ignition Control (used prior to April 1999)

W2001500 Pilot Burner (Honeywell) Spark Ignition

 

E2305400

Ignition Control, UT 100% Lockout

 

 

LP

both

 

After 1 Retry

 

RW0034500 Pilot Burner Nat Spark Johnson ...

both

E2305500

Ignition Control, UT, Continuous Retry

W0034600

Pilot Burner (Johnson) Standing

 

 

R0021300

Transformer, 40VA, 115/24V Kit ..

both

 

Pilot LP

both

E2103900

High Limit, Manual Reset Switch . new

W0036500

Thermocouple (Standing Pilot)

both

E2103800

Water Temp Control 60-105°F

new

10418815

Pilot Sensor Lead Assy - Std Pilot/

 

E2103600

Water Temp Sensor

new

 

Nat gas

both

RE2218701

Pressure Switch, Water

 

10418816

Pilot Sensor Lead Assy - Std Pilot/LP

 

RE0066200

Switch, Dual Aquastat

old

 

Spark Ign / LP & Nat

both

E0109200

Toggle Switch, 3-Position

both

R10418814

Pilot Ignition Lead Assy - Spark Ign

E0086800

Toggle Switch

both

L0050700

Orifice, Nat Gas, 0-2000 ft

both

10449518

Hi Tension Lead (orange/red wire

 

L0032600

Orifice, Nat Gas, 2001-5000 ft

both

 

from ignition ctrl to pilot lead)

both ..

500-600

L0050200

Orifice, Nat Gas, 5001-6000 ft

both

10449519

Hi Tension Lead (orange/red wire

 

L0050300

Orifice, Nat Gas, 6001-7000 ft

both

 

from ignition ctrl to pilot lead)

both ..

715-850

L0050400

Orifice, Nat Gas, 7001-10000 ft ...

both

10449520

Hi Tension Lead (orange/red wire

 

L0032900

Orifice, LP Gas, 0-4000 ft

both

 

from ignition ctrl to pilot lead)

both ..

1010-1430

 

3

Image 11
Contents Pentair Commercial Pool Heaters Ordering MegaTherm MT 500-5000 MBTU/h PowerMax PM 500-2000 MBTU/h472645 Rev a 05/22/06 Trademarks and disclaimersTable of Contents Standard Features MegaTherm MT MegaTherm MT Features and Options Code option L for MN and LDS Standard Features PowerMax PMBronze trim Kit for IRIPart Numbers PowerMax PM472645 Rev a 05/22/06 Litho in U.S.A Heater Name Model Sizes Doc. No Commercial Pool Heater PartsOrdering Parts Limited WarrantyReturn Under Warranty Our CommitmentBurner Trays MegaTherm Model MTSizes 500,000 1,825,000 BTU/h GAS SystemIndoor Boilers 8 Tubes MegaTherm AP, Sizes 500,000-1,825,000Electrical Components Optional Water SystemOutdoor Jacket Components MegaTherm MT, Sizes 500,000-1,825,000Jacket and Combustion Chamber Components Complete Tile AssembliesCross Reference for no Longer Available P/N’S Combustion Chamber Components Base Sizes 2,000,000 5,000,000 BTU/hMain GAS System Pilot GAS SystemCombustion Chamber Components Tile MegaTherm MT, Sizes 2,000,000-5,000,000BR021301 T20070003600,4050 T2007002Jacket Components Indoor PartsOutdoor Parts MegaTherm AP, Sizes 2,000,000-5,000,000Cross Reference for no Longer Available P/NS Sizes 500,000 5,000,000 BTU/h Gas Orifice Size ChartAP After April Sizes 500,000 1,825,000 Cement Tile Tile Assemblies MTAP Units Before April Sizes 500,000 1,825,000 Pyro Tile Sizes 2,000,000 5,000,000 Pyro Tile GAS Train / Combustion AIR Components PowerMax PMSizes 500,000 2,000,000 BTU/h Combustion Chamber ComponentsHeat Exchanger / Water Path Components PowerMax PM5C3304 5C300215C3002 5C3502472645 Rev a 05/19/06