Standard Features PowerMax PM (500-2000)
• | Automatic bypass | • Multiple operating gas valve/pressure | • | 115/24VAC 75VA power from class 2 | |
• ASME 160 psi working pressure heat |
| regulators |
| transformer | |
| exchanger | • Manual “A” gas valve | • | Manual reset high limit | |
• | ASME “H” stamp | • | Intake air filter | • | Automatic reset high limit |
• | Flanged water connections | • Multiple, removable burner trays | • | Electronic PID temperature control with | |
• | • | Stainless steel burners |
| LCD and touchpad | |
• | External header gaskets | • | • | PC board for electrical connections | |
• 75 psi (817 kPa) ASME |
| venting | • | Hot surface ignition | |
| rated pressure relief valve | • | Air pressure switch | • | On/Off toggle switch |
• | Flow switch | • | Burner site glass | • | Pump time delay |
• | Temperature and pressure gauge | • | 24V control system | • | Diagnostic lights |
|
|
|
| • Convertible indoor or outdoor operation | |
|
|
|
| • | Bronze trim |
Model Nomenclature
1 2
P M
3 | 4 | 5 | 6 | 7 |
P
8 9
A
10
C
11
C
12 13
2
14 15
N
SERIES
PM = POWERMAX
APPLICATION
P- POOL
SIZE
MBTU/h
0 5 0 0
0 7 5 0
1 0 0 0
1 2 5 0
1 5 0 0
1 7 5 0
2 0 0 0
FUEL |
| ALTITUDE |
| LOCATION |
| |
|
| C- INDOOR |
| |||
|
|
| OUTDOOR |
| ||
|
|
|
|
|
|
|
|
|
|
|
| FIRING MODE | |
|
|
|
|
| C- ON/OFF | |
|
|
|
|
|
|
|
| REVISION |
|
| PUMP |
| ||
| 2- SECOND |
|
|
| |||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
HEAT EXCHANGER |
| OPTIONS | |||||
B- GLASS LINED CAST IRON / COPPER / |
| ||||||
| BRONZE TRIM (Std) |
| |||||
K- BRONZE / COPPER |
| ||||||
P- GLASS LINED CAST IRON / CuNi / |
|
|
|
| |||
|
|
|
| ||||
| BRONZE TRIM |
|
|
|
| ||
S- BRONZE / |
|
|
|
| |||
|
|
|
|
|
|
|
|
Pennant Option Descriptions
Code option J: for
The changes made to the standard Pennant to achieve code option J are as follows:
•Adds manual reset high and low gas pressure switches
•Adds gas regulator
•Changes ignition control from the standard
Kit for IRI:
This kit is added to a Pennant unit with code option J. In total, code option J with the IRI kit:
•Adds manual reset high and low gas pressure switches
•Adds safety valve with gas regulator
•Adds leak test valve for additonal safety
•Adds normally open vent valve
•Changes ignition control from the standard
Code option L: for MN and LDS |
|
| |
Sizes 500 to 1000: | Sizes 1250 to 2000: | ||
• Adds safety valve with regulator | • Adds solenoid safety valve | ||
• | Adds high gas pressure switch | • | Adds motorized safety valve with proof of closure |
• | Adds leak test valve | • | Adds leak test valve |
•Adds high and low gas pressure switches
6