Cisco Systems 8600 Series manual DC Power Entry Module with Conduit Box

Models: 8600 Series

1 424
Download 424 pages 24.57 Kb
Page 308
Image 308

Replacing Parts

Figure 11-3 DC Power Entry Module with Conduit Box

Conduit cover screws

Conduit box cover

Conduit connection (customer supplied)

90° terminal lug (3 places)

ON CB1

OFF 0

ON CB1

OFF 0

USE COPPER

CONDUCTORS

ONLY

USE COPPER

CONDUCTORS

ONLY

+RTN

 

 

 

48V

H8005

Step 6 If a conduit box is used, remove it. Remove the ground screw above the middle terminal block connector (see Figure 11-3).

Step 7 Remove the two standoffs on each side of the terminal block and pull the conduit box straight back. Set it aside. Do not try to remove the terminal block.

Step 8 Loosen the two captive screws (at the bottom corners) holding the PEM. Loosen the two connector jackscrews adjacent to the finger pull.

Step 9 Grasp the finger pull lip at the top of the PEM and pull the unit straight out. Step 10 Replacement is the reverse of removal.

11-10Cisco BPX 8600 Series Reference

Page 308
Image 308
Cisco Systems 8600 Series manual DC Power Entry Module with Conduit Box