T3 and E3 Line Modules (LM-3T3 and LM-3E3)

Table 4-2

BNI Front Panel Card Failure Indications

 

 

 

 

act

stby

fail

Failure Description

 

 

 

 

on

off

on

Non-fatal error detected; card is still active.

 

 

 

 

off

on

on

Non-fatal error detected; card is in standby mode.

 

 

 

 

off

blinking

on

Fatal error detected; card is in a reboot mode.

 

 

 

 

on

on

on

Card failed boot load and operation is halted.

 

 

 

 

T3 and E3 Line Modules (LM-3T3 and LM-3E3)

The Line Modules for the BNI-T3 and BNI-E3 front cards are back cards used to provide a physical interface to the transmission facility. The LM-3T3 is used with the BNI-T3 and the LM-3E3 with the BNI-3E3. The Line Module connects to the BNI through the StrataBus midplane. Two adjacent cards of the same type can be made redundant by using a Y-cable at the port connectors. All three ports on a card must be configured the same.

Refer to Figure 4-4, Figure 4-5,and Table 4-3which describe the faceplate connectors of the LM-3T3 and LM-3E3. There are no controls or indicators.

The LM-3T3 provides the following features:

BNC connectors for 75-ohm unbalanced signal connections to the transmit and receive of each of the three ports.

Transformer isolation from the trunk lines.

Metallic relays for line loopback when in standby mode.

A final node loopback is found at the end of the LM-3T3 or LM-3E3 card. This is a metallic loopback path that uses a relay contact closure. It is a near-end loopback path only; the signal is looped at the final output stage back to circuits in the node receive side. It is only operated when the corresponding front card is in standby.

Table 4-3

LM-3T3 and LM-3E3 Connectors

 

 

 

No

Connector

Function

 

 

 

1

PORT 1 RX - TX

BNC connectors for the transmit and receive T3/E3 signal to/from ATM

 

 

 

trunk 1.

 

 

 

2

PORT 2 RX - TX

BNC connectors for the transmit and receive T3/E3 signal to/from ATM

 

 

 

trunk 2.

 

 

 

3

PORT 3 RX - TX

BNC connectors for the transmit and receive T3/E3 signal to/from ATM

 

 

 

trunk 3.

 

 

 

 

4-8Cisco BPX 8600 Series Reference

Page 100
Image 100
Cisco Systems 8600 Series manual T3 and E3 Line Modules LM-3T3 and LM-3E3, LM-3T3 and LM-3E3 Connectors, Port 1 RX TX