Cisco Systems 8600 Series DIP Switches, Table D-2 Front Panel Indicators Color Description, FT2

Models: 8600 Series

1 424
Download 424 pages 24.57 Kb
Page 390
Image 390

Equipment Description

Front Panel Indicators

The front panel of the system provides LED indicators for the alarm status of the transmit and the receive T3 and the T2 interfaces (refer to Table D-2and Figure D-2). Also on the front panel are indications for power and for operating status (Fail/Active).

The Overflow LED indicates that the cell rate coming from the T3 interface exceeds the bandwidth of the T2 facility and that the Interface Adapter buffer has overflowed.

Table D-2

Front Panel Indicators

 

 

 

 

 

Indicator

 

Color

Description

 

 

 

 

T3

Receive Status—AIS

Green

Alarm Indication signal detected on the RCV T3 line.

 

 

 

 

T3

Receive Status—RAI

Yellow

Remote Alarm Indication signal detected on the receive T3

 

 

 

 

line.

 

 

 

 

T3

Receive Status—LOS

Red

Loss of receive T3 signal.

 

 

 

 

 

T3

Receive—LOF

 

Red

Loss of frame on receive T3 signal.

 

 

 

 

T3

Transmit Status—AIS

Green

Alarm Indication signal detected on the transmit T3 line.

 

 

 

 

T3

Transmit Status—RAI

Yellow

Remote Alarm Indication signal detected on the transmit T3

 

 

 

 

line.

 

 

 

 

T3

Transmit Status—LOS

Red

Loss of transmit T3 signal.

 

 

 

 

T2

Receive Status—AIS

Green

Alarm Indication signal detected on the RCV T2 line.

 

 

 

 

T2

Receive Status—RAI

Yellow

Remote Alarm Indication signal detected on the receive T2

 

 

 

 

line.

 

 

 

 

T2

Receive Status—LOS

Red

Loss of receive T2 signal.

 

 

 

 

 

T2

Receive—LOF

 

Red

Loss of frame on receive T2 signal.

 

 

 

 

T2

Transmit Status—AIS

Green

Remote Alarm Indication signal detected on the transmit T2

 

 

 

 

line.

 

 

 

 

T2

Transmit Status—RAI

Yellow

Loss of transmit T2 signal.

 

 

 

 

T2

Transmit Status—LOS

Red

Loss of frame on transmit signal.

 

 

 

 

Overflow

 

Red

T3 receive cell rate exceeds the T2 line capacity.

 

 

 

 

FT2

 

Red

Fractional T2 indication for future use.

 

 

 

 

T3/T2 loop

 

Red

Indicates the unit is in loop back mode, external toward the T3

 

 

 

 

and T2 line interfaces.

 

 

 

 

Active/Fail

 

Green/Red

Upon power up the system will go through extensive self tests.

 

 

 

 

If self-test passes, the Active/Fail LED will be green; if

 

 

 

 

self-test fails the LED will be RED.

 

 

 

 

Power

 

Green

Power ON indication.

 

 

 

 

 

DIP Switches

The adapter has two front panel DIP switches, a two-position (SW-1), and a 12-position (SW-2) switch. SW-1 controls the configurations that may interrupt operation and should be done through a two-step operation. SW-2 enables all other configuration parameters.

D-4Cisco BPX 8600 Series Reference