Configuration Example

Sample Display:

n4

TN

SuperUser

 

BPX 15

9.1

Apr. 4 1998

16:40 PST

Port/Trunk : 4.1

 

 

 

 

 

 

Maximum PVC

LCNS:

 

256

Maximum PVC Bandwidth:26000

 

Min Lcn(1) : 0 Min Lcn(2) : 0

 

 

 

 

 

Partition 1

 

 

 

 

 

 

 

Partition State :

 

Enabled

 

 

 

 

Minimum VSI

LCNS:

 

512

 

 

 

 

Maximum VSI

LCNS:

 

7048

 

 

 

 

Start VSI VPI:

 

2

 

 

 

 

End VSI VPI

:

 

15

 

 

 

 

Minimum VSI

Bandwidth :

26000

Maximum VSI Bandwidth :

100000

Last Command: cnfrsrc 4.1 256 26000 1 e 512 7048 2 15 26000 100000

Next Command:

Note It is possible to have PVCs terminating on the Tag Switch Controller itself, as shown in Figure 9-4.This example reserves approximately 10 Mbps (26000 cells/sec) for PVCs, and allows up to 256 PVCs on the switch port connected to the TSC.

Note The VSI max and min logical connections (LCNs) will determine the maximum number of tag virtual connections (TVCs) that can be supported on the interface. The number of TVCs required on the interface depends on the routing topology of the tag switch.

Note By default the TSC will use either a starting VSI VPI of 1 or 2 for tag switching, whichever is available. If both are available, a starting VSI VPI of 1 is used. The VPI range should be 2-3 on a BPX VSI connected to a 7200 or 7500 AIP. If VPI 2 is not to be used, the tag switching VPI interface configuration command can be used on the TSC to override the defaults

Note The VSI range for tag switching on the BPX switch is configured as a VSI partition, usually VSI partition number 1. VSI VPI 1 is reserved for autoroute, so the VSI partition for tag switching should start at VPI 2. Two VPIs are sufficient for the current release, although it may be advisable to reserve a larger range of VPIs for later expansion, for example, VPIs 2-15.

Step 7 Ports 4.2 and 4.3 are connected to other tag switch router ports in this example and support TVCs across the network. Configure the VSI partitions for ports 4.2 and 4.3 by repeating the procedures in the previous step, but entering 4.2 and 4.3, where applicable.

Maximum VSI LCNs (logical connection numbers) determine the number of connections that can be made to each port. For a description of how the LCNs may be assigned to a port, refer to Configuring VSI LCNS on page 12.

9-22Cisco BPX 8600 Series Reference

Page 250
Image 250