Troubleshooting the BPX Switch

Table 11-1

Troubleshooting the BPX Switch (Continued)

 

 

 

 

 

Symptom

 

Probable Cause

Remedy

 

 

 

 

BXM Port LED is red or orange

Trunk is in local or remote alarm.

Use NMS dsptrk screen to confirm trouble.

(BXM configured for trunk

 

 

 

mode).

 

 

 

 

 

 

 

 

BNI Port LED is red or orange.

Trunk is in local or remote alarm.

Use NMS dsptrk screen to confirm trouble. Use short BNC

 

 

 

loopback cable at LM-BNI connectors for local test of trunk.

 

 

 

Loop trunk at DSX-3 crossconnect to check cable.

 

 

 

 

No BXM card or port LED on.

No trunks or lines, as applicable

Up at least one of the trunks or lines, as applicable, associated

 

 

on card are upped. Card has not

with the card (Trunks if BXM configured for trunk

 

 

necessarily failed.

mode, lines if BXM configured for port mode).

 

 

 

 

No BME card or port LED on.

No lines are upped. Card has not

Up at least one of lines, as applicable, associated with the

 

 

necessarily failed.

card.

 

 

 

 

No BNI card or port LED on.

No trunks on card are upped.

Up at least one of the trunks associated with the card.

 

 

Card not necessarily failed.

 

 

 

 

 

 

BXM Port LED is red or orange

Line is in local or remote alarm.

Use NMS dsplns screen to confirm trouble.

(BXM configured for port

 

 

 

mode)

 

 

 

 

 

 

 

 

BME Port LED is red or orange

Line is in local or remote alarm.

Use NMS dsplns screen to confirm trouble.

 

 

 

 

ASI Port LED is red or orange.

Line is in local or remote alarm.

Use NMS dsplns screen to confirm trouble.

 

 

 

 

No ASI card or port LED on.

No lines on card are upped. Card

Up at least one of the two lines associated with the card.

 

 

not necessarily failed.

 

 

 

 

 

 

BCC fail LED flashing

Downloading system software or

Wait for download to complete.

 

 

configuration data.

 

 

 

 

 

 

BCC LAN LED flashing

Normal for node connected to

Check that the cabling to the NMS is firmly connected to the

 

 

NMS terminal over Ethernet. If it

LAN port on the LM-BCC back card. An alternate

 

 

does not flash, there may be

connection is to the control port.

 

 

problems with node to NMS data

 

 

 

 

path.

 

 

 

 

 

 

No BCC card LED on.

Preparing to download new

Wait for download to begin.

 

 

software (momentary condition).

 

 

Command issued to run a software rev. that was not available in the network.

Check that proper s/w rev. is available on another node or on NMS.

Repair and Replacement 11-3