Displaying the Status of Cards in the Node

When a card indicates a failed condition on the alarm summary screen, use the Display Cards

(dspcds) command to display the status of the circuit cards on a node. The information displayed for each card type includes the card slot number, software revision level, and the status of the card. The possible status description for each card type are listed in Table 11-2.Refer to the Cisco WAN Switching Command Reference for more information on the Display Cards command.

Table 11-2

Card Status for the BPX Switch

 

 

 

Card Type

Status1

Description

All card types

Active

Active card.

 

 

 

 

Active - F

Active card with no terminal failure.

 

 

 

 

Standby

Standby card.

 

 

 

 

Standby - F

Standby card with no terminal failure.

 

 

 

 

Standby - T

Standby card performing diagnostics.

 

 

 

 

Standby - F -T

Standby card with no terminal failure performing diagnostics.

 

 

 

 

Failed

Card with terminal failure.

 

 

 

 

Unavailable

Card is present but it may be in one of the following states:

 

 

a. The node does not recognize the card.

 

 

b. The card is running diagnostics.

 

 

 

 

Down

Downed card.

 

 

 

 

Empty

No card in that slot.

 

 

BCC

Same status as for all card types, plus:

 

 

 

 

Updating

Standby BCC downloading the network configuration from an

 

 

active BCC.

 

 

Note: Red FAIL LED flashes during updating.

 

 

 

 

Cleared

BCC is preparing to become active.

 

 

 

 

Downloading

There are downloader commands that appear when the system

 

Software

is down- loading software to the BCC.

 

 

 

 

Minor

BCC Redundancy alarm indicates node is configured for

 

 

redundancy but no standby BCC is equipped.

 

 

 

1.Cards with an F status (no terminal failure) are activated only when necessary. Cards with a failed status are never activated.