LM-BCC Cabling

External Clock Input Cabling

This cabling is for making external clock connections for use by the BCC-32, BCC-3, and BCC-4 backcards. The BCC-32 uses the BCC-bc backcard, and the BCC-3 and BCC-4 both use the BCC-3-bc backcard.

T1 Clock Cabling

Table B-8through Table B-11lists T1 clock cabling details.

Table B-8

External Clock Cabling

 

 

Cable Parameter

Description

 

 

 

Cable Type:

 

22 AWG, ABAM individually shielded twisted pair. Two pair per T1 line (1

 

 

transmit and 1 receive).

 

 

 

Cable Connector:

 

Male DB-15 subminiature. See Table B-10through Table B-11for pinouts.

 

 

Max. Cable Length:

533 ft (162 m.) maximum between the BPX switch and the first repeater or

 

 

CSU. Selection of cable length equalizers.

 

 

 

Table B-9 T1 Connection to XFER TMG on BCC-bc

Pin # Description

1Transfer timing ring

2Transfer timing tip

3& 4 Transfer timing shield

Table B-10 T1 Connection to EXT TMG on BCC-bc

Pin # Description

2Receive pair shield

3Receive tip

11

Receive Ring

 

 

Table B-11

T1 Connection to EXT 1 or EXT 2 on BCC-3-bc

 

 

 

Pin #

Description

Function

 

 

 

1

Transmit tip

Transmit T1 timing signal synchronized to the node

 

 

 

 

2

Transmit pair shield

 

 

 

 

 

3

Receive tip

Receive clock for synchronized clock source for node

 

 

 

 

4

Receive pair shield

 

 

 

 

 

 

7

Transfer timing tip

 

 

 

 

 

 

8

Transfer timing shield

 

 

 

 

 

 

9

Transmit ring

 

 

 

 

 

 

11

Receive ring

 

 

 

 

 

 

15

Transfer timing ring

 

 

 

 

 

 