LM-BCC Cabling

E1 Clock Cabling

Table B-12through Table B-15lists E1 clock cabling details.

Table B-12

E1 Connector Pin Assignments for External Clock

 

 

 

Connector

 

Description

 

 

 

Cable Type:

 

75-ohm coax cable for unbalanced connection or 100–120-ohm twisted pair

 

 

for balanced connection. Two cables/pairs (1 transmit, 1 receive) per E1 line.

 

 

 

Cable Connector:

 

Two female BNC for unbalanced connection; male DB15 for balanced

 

 

connection. See Table B-13and Table B-15for pinouts.

 

 

Max. Cable Length:

Approx. 100 meters maximum between the BPX switch and the first repeater

 

 

or CSU. Equalizer for cable length.

 

 

 

Table B-13

E1 Connection 75 Ohm to EXT TMG on BCC-bc or BCC-3-bc

 

 

Connector

Description

 

 

BNC

Receive E1 from trunk

 

 

Table B-14 E1 Connection 100/120 Ohm to EXT TMG on BCC-bc

Pin # Description

2Receive pair shield

3Receive tip

11

Receive Ring

 

 

Table B-15

E1 Connection 100/120 Ohm to EXT 1 or EXT 2 on BCC-3-bc

 

 

 

Pin #

Description

Function

 

 

 

1

Transmit tip

Transmit T1 timing signal synchronized to the node

 

 

 

 

2

Transmit pair shield

 

 

 

 

 

3

Receive tip

Receive clock for synchronized clock source for node

 

 

 

 

4

Receive pair shield

 

 

 

 

 

 

7

Transfer timing tip

 

 

 

 

 

 

8

Transfer timing shield

 

 

 

 

 

 

9

Transmit ring

 

 

 

 

 

 

11

Receive ring

 

 

 

 

 

 

15

Transfer timing ring

 

 

 

 

 

 

BPX Switch Cabling Summary B-5

Page 375
Image 375
Cisco Systems 8600 Series manual E1 Clock Cabling, Table B-12through Table B-15lists E1 clock cabling details