B. Design and Installation Considerations

B. Design and Installation Considerations

Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the out- side. No additional outside air source is required.

Installation MUST comply with local, regional, state and national codes and regulations. Consult insurance carrier, local building inspector, re of cials or authorities having jurisdiction over restrictions, installation inspection and permits.

Before installing, determine the following:

Where the appliance is to be installed.

The vent system con guration to be used.

Gas supply piping.

Electrical wiring requirements.

Framing and nishing details.

Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a quali ed service technician, service agency or your dealer.

C. Tools and Supplies Needed

Before beginning the installation be sure that the following tools and building supplies are available.

Tape measure

Framing material

Pliers

High temperature caulking

material

 

Hammer

Phillips screwdriver

Gloves

Framing square

Voltmeter

Electric drill and bits (1/4 in.)

Plumb line

Safety glasses

Level

Reciprocating saw

Manometer

Flat blade screwdriver

Non-corrosive leak check solution

1/2 - 3/4 in. length, #6 or #8 Self-drilling screws

One 1/4 in. female connection (for optional fan).

WARNING! Risk of Fire, Explosion or Electric Shock! DO NOT use this appliance if any part has been under wa- ter. Call a quali ed service technician to inspect the appli- ance and to replace any part of the control system and/or gas control which has been under water.

D. Inspect Appliance and Components

Carefully remove the appliance and components from the packaging (refer to Figure 4.2).

-Remove refractory from back of unit by removing the screws from shipping bracket.

-Remove screws from shipping brackets before trying to remove unit from pallet.

-Remove and save screws from andirons for later installation.

-Remove screw from top of each carrying handle. Handles have been provided to assist in moving the unit.

The vent system components and decorative doors and fronts are shipped in separate packages.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and bene t.

WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, incomplete or substitute components. Keep appliance dry.

Refractory

Andirons

Shipping Brackets

Figure 4.2 Refractory Shipping Location, Brackets

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged appliance or vent system component.

Modi cation of the appliance or vent system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a re hazard.

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08