Quadra-Fire QFP44 owner manual Top Vent - Vertical Termination, No Elbow, Two Elbows

Models: QFP44

1 68
Download 68 pages 49.02 Kb
Page 32
Image 32
2. Top Vent - Vertical Termination

2. Top Vent - Vertical Termination

No Elbow

12 ft (3.66 m) min.

60 ft (18.29 m) max.

Figure 7.7

Two Elbows

12 ft (3.66 m) min. No ElbowTwo Elbows12 ft (3.66 m) min.  60 ft (18.29 m) max. 60 ft (18.29 m) max.

Maximum horizontal run is 100% of vertical, but cannot exceed 18 ft (5.49 m)

Figure 7.8

Note: If installing a vertical vent/ter- mination off the top of the appliance, the ue restrictor should be used. See Section 14.E. for necessary damper adjustment.

3 ft m (.91

32

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08

Page 32
Image 32