D. Electrical Service and Repair

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.

Figure 12.1 Wiring Diagram

E. Junction Box Installation

If the box is being wired from the OUTSIDE of the appli- ance:

Remove the cover plate located on the outer shell - right side (see Figure 12.2).

Install the supplied Romex™ connector in the cover plate.

Feed the necessary length of wire through the connector.

Make all necessary wire connections and reattach the cover plate to the outer shell.

If the box is being wired from the INSIDE of the appli- ance:

Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.3).

Pull the electrical wires from outside the appliance through this opening into the valve compartment.

Feed the necessary length of wire through the connector.

Make all necessary wire connections to the junction box/ receptacle and reassemble the junction box/receptacle to the outer shell.

 

 

Romex

 

 

Connector

 

 

14/2WG

 

 

Cover Plate

 

 

outside firebox

WHT

 

 

BLK

 

WHT

BLK

Copper

 

 

 

 

GRN wire

ground attached

 

to GRN screw with

 

inside box

 

GRN wire

 

 

Figure 12.2 Junction Box Detail

 