Quadra-Fire QFP44 Troubleshooting continued, Symptom, Possible Cause, Corrective Action

Models: QFP44

1 68
Download 68 pages 49.02 Kb
Page 59
Image 59

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

3. (Continued)

C. Failed valve.

Turn the valve knob to the ON position. Place the ON/OFF switch

 

 

in the ON position. Check the millivolt meter a the thermopile

 

 

terminals. The millivolt meter should read greater than 125mV. If the

 

 

reading is acceptable, and if the burner does not come on, replace

 

 

the gas valve.

 

 

 

 

D. Plugged burner ori ce.

Check the burner ori ce for stoppage. Remove stoppage.

 

 

 

 

E. Wall switch or wires.

Check the wall switch and wires for proper connections. Place the

 

 

jumper wires across the terminals at the wall switch. If the burner

 

 

comes on, replace the wall switch. If the wall switch is OK, place

 

 

the jumper wires across the wall switch wires at the gas valve. If the

 

 

burner comes on, the wires are faulty or connections are bad.

 

 

 

4. Frequent pilot outage

A. Pilot ame may be too high or

Clean thermocouple and adjust the pilot ame for proper ame

problem.

too low, or blowing out (high

impingement. Follow lighting instructions carefully.

 

pressure), causing pilot safety

 

 

to drop out.

 

5. The pilot and main

A. No LP in tank.

Check the LP (propane) tank. Re ll the fuel tank.

burner extinguish while in

 

 

B. Improper gas inlet pressure.

Verify with manometer. NG should read 5-14 inches w.c. LP should

operation.

 

read 10-14 inches w.c.

 

 

 

C. Inner vent pipe leaking exhaust

Check venting system for damage. Replace/repair improperly

 

gases back into the system.

assembled pipe sections.

 

 

 

 

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace glass panel

 

 

assembly.

 

E. Failed thermopile or

Replace pilot if necessary.

 

thermocouple.

 

 

F. Improper vent cap installation.

Check for proper installation and freedom from debris or blockage.

 

 

 

6. Glass soots.

A. Flame impingement.

Adjust the log set so that the ame does not excessively impinge on

 

 

it. Refer to log instructions.

 

B. Improper air shutter setting.

Refer to manual for shutter set points. Ensure that set point is

 

 

correct for appliance/gas type. If unit has adjustable shutter, it may

 

 

be necessary to increase shutter opening.

 

C. Debris around air shutter.

Inspect the opening at the base of the burner. NO MATERIAL

 

 

SHOULD BE PLACED IN THIS OPENING.

7. Flame burns blue and lifts

A. Insuf cient oxygen being

Ensure that the vent cap is installed properly and free of debris.

off burner.

supplied.

Ensure that the vent system joints are tight and have no leaks.

 

 

Ensure that no debris has been placed at the base of, or in the area

 

 

of the air holes in the center of the base pan beneath the burner.

 

 

 

 

 

Ensure that the glass is tightened properly on the unit, particularly

 

 

on top corners.

Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08

59