General

Weight, approx:

 

73 lb. (33.2 kg.) empty BPX shelf, w/fans but no PS.

 

 

6 lb. (2.7 kg.) each card.

 

 

 

18 lb. (8.2 kg.) empty AC Power Supply Tray.

 

 

16 lb. (7.3 kg.) each AC Power Supply.

 

 

 

2 lb. (0.9 kg.) each DC Power Entry module.

Clearance Requirement:

At least 30 inches front and rear clearance; nominal 12 inch side

 

 

clearance.

 

Power Source:

 

AC system: 180 – 264 VAC, 47 to 63 Hz.

 

 

DC system: –42 to –56 VDC.

 

Power Requirements:

AC BPX-15: 13 A at 180 VAC (2300 VA).

 

 

DC BPX-15: 40 A at –42 VDC (1680W).

Input Power Connector:

AC: 3-conductor IEC receptacle. 8 feet (2.4 m.) power cord

 

 

supplied.

 

 

 

DC: 3 Ring lug screw terminal connectors.

Circuit Breakers:

 

AC: 15 A on AC power supply assembly.

 

 

DC: 40A on power entry module.

 

Fuses:

 

Individual Backplane Card slot fuses, F1 through F3 for Fans 1

 

 

through 3, and F4 through F18 for card slots 1 through 15,

 

 

5A-120VAC rating.

 

Operating Environment:

Operating Conditions are listed in Table A-1.

Shock:

 

Withstands 10G, 10 ms. at 1/2 sine wave.

Vibration:

 

Withstands 1/4 G, 20–500 Hz.

 

Heat Transfer to Room:

Up to 7200 BTUs depending on node configuration.

Table A-1

Ambient Temperature and Humidity Limits

 

 

 

 

 

 

 

 

 

Limits

 

 

 

 

 

 

Conditions

 

 

Fahrenheit

Centigrade

 

 

 

 

Operating Temperature

 

+40 to +100 degrees

+4.5 to +38 degrees

Recommended

 

 

+68 to + 86 degrees

+20 to +30 degrees

 

 

 

 

Short-Term Temperature1

 

+35 to +120 degrees

+1.7 to + 49 degrees

Operating Relative Humidity

 

20% to 55%

 

 

 

 

(non-condensing)

 

 

 

 

 

Short-Term Relative Humidity

 

10% to 80%

 

 

 

 

non-condensing

 

 

 

 

 

 

1. Room temperature refers to conditions at a location 5 feet above the floor and 15 inches in front of the equipment.

A-2Cisco BPX 8600 Series Reference

Page 360
Image 360
Cisco Systems 8600 Series manual General