Raypak 402B warranty Heat Exchanger, Controls, Gas Train Options, Burner, Construction, Venting

Page 1

Job:

 

 

 

 

 

Hi Delta® - Type P

Engineer:

 

 

 

 

 

Commercial Pool Heaters

Contractor:

 

 

 

 

 

 

 

 

 

 

Models 302B & 402B

Prepared By:

 

Date:

 

 

 

 

 

 

 

 

Model:

 

Indoor/Outdoor:

 

 

MBTUH Input:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sealed Combustion Chamber

100% Factory Fire Tested

Efficiency: 85%

Minimum Non-condensing Inlet Temperature: 105°F

Thermal Shock Proof Heat Exchanger

Limited Twenty-year Thermal Shock Warranty

Limited Five-year Heat Exchanger Warranty

Diagnostic Center with Fault History

PolyTuf Powder Coated Cabinet

No Combustible Floor Shield Required

Fan-assisted

Non-ferrous Bypass

Patented Burner Security Blanket

Heat Exchanger

￿Bronze Headers

￿ASME Inspected and Stamped 160 PSIG Working Pressure

￿National Board Approved

￿Cupro Nickel Finned Tubing

￿ASME Steel Tube Sheet

￿Silicone High Temp O-Rings

￿125 PSIG ASME Pressure Relief Valve

￿Temperature and Pressure Gauge

￿Water Connections

Left – Standard

Right – Option A-6

￿Bronze Pump, 1/3 HP, 120V, 60Hz

￿Non-Ferrous Pool Bypass Assembly with Automatic Control

Controls

￿120V, 60Hz, 1Power Supply

￿120/24V 60Hz Transformer

￿100% Shut-off/Lockout

￿Hot Surface Ignition

￿Remote Flame Sensor

￿High Limit Control, Auto Reset

￿On/Off Power Switch

￿Manual Shut-off, Front-mounted

￿Flow Switch

￿Blocked Vent Pressure Switch

￿Combustion Air Proving Switch

￿Economaster Pump Time Delay

￿Poolstat

Gas Train

Options

 

￿

Gas Pressure Regulator

 

 

C-6

Ignition Module, Manual Reset

￿

Safety Shut-off Valve

 

 

D-21

TruSeal™ Direct Vent

￿

Firing Control Valve

 

 

F-10

Low Water Cut-Off, Remote

￿

On/Off Firing

 

 

 

 

Probe

￿

Fuel

 

 

I-1

High Limit Control, Auto Reset

 

Natural Gas

 

 

S-1

Low Gas Pressure Switch,

 

Propane Gas

 

 

 

 

Manual

￿ Design Certified ANSI Z21.56/

 

 

S-2

High Gas Pressure Switch,

 

CSA 4.7

 

 

 

 

Manual

Burner

 

 

X-1

SureRack™ Kit

 

 

X-2

SureRack Add-on

￿ Ultra-low NOx:

 

 

 

 

 

 

 

 

Less Than 30 PPM

 

 

 

 

 

 

Regulatory Agency Requirements

Construction

 

G-1

CSD-1

 

 

 

￿Indoor/Outdoor Construction

￿Enclosed Front Controls

Venting

￿Vent Location

Top – Standard

Rear – Option D-14

￿Vent Termination Cap

Outdoor – Option D-11

Indoor, Horizontal –

Option D-15

Indoor, Vertical (by others)

￿Combustion Air

In-Line Filter Kit (TruSeal

L

 

only) – Option D-17

W

Air Intake Elbow –

 

Option D-16

 

Catalog No.: 6000.312D

Effective: 8-15-08

Replaces: 2-1-08

Image 1
Contents Controls Heat ExchangerGas Train Options BurnerHi Delta Type P
Related manuals
Manual 60 pages 4.29 Kb

402B, 302B specifications

Raypak is a prominent name in the heating industry, particularly known for its advanced technology and robust design in residential and commercial heating solutions. Two of their notable models, the Raypak 302B and 402B, exemplify innovation and efficiency in hydronic heating systems, designed to meet diverse needs while ensuring optimal performance.

The Raypak 302B and 402B are high-efficiency boilers that utilize gas-fueled systems. The 302B model has a heating capacity of 302,000 BTU/h, while the 402B boasts a maximum capacity of 402,000 BTU/h. This range of heating output makes these models suitable for a variety of applications, from residential heating needs to larger commercial spaces that require a reliable heat source.

One of the standout features of the Raypak 302B and 402B is their use of fire-tube heat exchanger technology. This design promotes efficient heat transfer and allows for lower emissions, thus minimizing the environmental impact. The fire-tube design also contributes to a longer lifespan and reduced maintenance costs, making these boilers a cost-effective solution over time.

Equipped with advanced control systems, the Raypak 302B and 402B ensure precise temperature regulation and improved energy usage. The digital display provides real-time feedback and diagnostics, enhancing user experience and simplifying troubleshooting. These models are also compatible with various building management systems, providing users with versatility in integration to optimize building performance.

In addition to their technological advancements, these boilers are designed with user safety and convenience in mind. They include features such as built-in safety controls, easy access for service and maintenance, and a compact footprint to fit into tight spaces. Their robust construction ensures durability, which is crucial for systems that operate under high demand.

Moreover, both models have been engineered to succeed in various climates, making them reliable choices for users in diverse geographical locations. With their energy-efficient operation, reliable performance, and advanced features, the Raypak 302B and 402B embody quality and innovation in the heating market, ensuring comfortable environments while lowering energy costs and environmental footprints.