Zenoah EHT601D, EHT751S owner manual Muffler After 100 Hours of USE, Maintenance Before Storage

Page 36

F19

F20

English

6. MAINTENANCE

MUFFLER

AFTER 100 HOURS OF USE

1.Remove the muffler, insert a screwdriver into the vent, and wipe away any carbon buildup. Wipe away any carbon buildup on the muffler exhaust vent at the same time. (F19)

(1)screw driver

(2)muffler

2.Tighten all screws, bolts, and fittings.

3.Check to see if any oil or grease has worked its way in between the clutch lining and drum, and if it has wipe it away using oil-free, lead-free gasoline.

MAINTENANCE

BEFORE

 

STORAGE

 

 

 

 

 

 

IMPORTANT

 

 

 

 

 

 

Use a dry rag to wipe any fuel which has been spilled onto the unit.

(F20)

1.Extract fuel from the tank and run the engine until it stops naturally.

2.Remove the spark plug and put in 1~2 cc of 2-cycle oil in the engine. Pull the starter rope 2~3 times, set the plug back, and stop it at the contraction position.

3.Apply anti-rust oil to the metal parts such as the throttle wire etc., put the cover on the blade, and keep it indoor avoiding dampness.

36

Image 36
Contents EHT751S EHT601D Contents Page Parts Location Page Symbols on the Machine Page Safety Precautions Page Working Gear and Clothing a. When using your hedge-trimmer Page Things to Check Before Using Your HEDGE-TRIMMER Handling of FuelPage Safety Precautions Page Kickback Safety Precautions Page Maintenance Safety Precaution Page Safety Precautions Page Fuel Mixing ratiosPage Operation Starting the Engine WarningPage HOW to USE Cutting Work WarningF5 eHT601D Maintenance Safety Lock F10 WarningF10 AIR Cleaner F12 ANTI-VIBRATION System F11 WarningF11 F12 Fuel Filter F13 WAY of the Cooling AIR F14Spark Plug F15 F13 F14 F15 Adjusting Carburetor F17 Gearcase F16F16 F17 F18 Maintenance Before Storage Muffler After 100 Hours of USEF19 F20 Specifications