Safety / Operation | 2 |
ATTENTION: Read carefully before attempting to install, operate or service your pump. Protect your- self and others by observing all safety information and additional instructions included with this equip- ment. Failure to comply with instructions could result in personal injury and/or property damage!
Retain for future reference.
DESCRIPTION
This submersible pump is intended for water removal from swimming pool covers. Unit is constructed of
SPECIFICATIONS
Power supply required | 115V, 60 HZ. |
Motor | 16 Watt |
Motor duty | Continuous |
Thermal Protector | Automatic |
Liquid Temp. Range | Max. 77°F (25°C) |
Operation Position | Horizontal |
Circuit Requirement (min.) | 10 Amp |
Dimensions (Overall) | |
Power Cord Set | Vinyl, |
Discharge | .....Horizontal Male Garden Hose Thread | ||
| PERFORMANCE |
| |
|
|
| |
| GPH IN TOTAL FEET |
| |
| 3' | 5' | 7' |
2105 | 300 | 170 | 0 |
NOTICE: This unit is not designed for applications in- volving salt water or brine!
GENERAL SAFETY
INFORMATION
1.Know the pump application, limitations, and potential hazards.
Do not use in explosive atmospheres. Pump water only with this pump. Failure to follow this warning can result in per- sonal injury and/or property damage.
2.Make certain that the power source conforms to the requirements of your equipment.
3.Disconnect power before servicing.
4.Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.
5.Check hoses for weak or worn condition before each use, making certain that all connections are secure.
6.Periodically inspect pump and system compo- nents. Perform routine maintenance as required (See MAINTENANCE Section).
7.Provide a means of pressure relief on pumps whose discharge line can be
8.Personal Safety:
a.Wear safety glasses at all times when work- ing with pumps.
b.Keep work area clean, uncluttered and prop- erly lighted – replace all unused tools and equipment.
c.Keep visitors at a safe distance from the work area.
d.Make workshop
9.This equipment is only for use on 115 volt (sin- gle phase) and is equipped with an approved 3- conductor cord and
To reduce the risk of electric shock, be certain that it is connected to a prop- erly grounded, Ground Fault Circuit Interrupter (GFCI) protected,
Where a
10.Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Replace or repair damaged or worn cords immediately.
11.Do not touch an operating motor. Modern motors can operate at high temperatures.
12.Power Supply: Pump is designed for 115V., 60 HZ. operation and requires a circuit of 10 amperes or more capacity. It is supplied with a
OPERATION
Risk of electric shock. Do not han- dle a pump or pump motor with wet hands or when standing on wet or damp surface, or in water.
1.Hand tighten
2.Thread garden hose onto adapter hand tight. Then turn one quarter turn tighter with pliers to seal. Make sure the washer is in the end of the garden hose.
3.Straighten out the garden hose as much as possible.
For parts or assistance, call Simer Customer Service at