System Start Up _________________________________________________________
The following is a recommended procedure that will protect system components during system
Table 3: Recommended System Fill Rate
Pipe Size | Flow | Velocity | Pipe Size | Flow | Velocity | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
in. | cm | GPM | LPM | ft/sec | m/sec | in. | cm | GPM | LPM | ft/sec | m/sec |
1/2 | 1.3 | 2 | 7.6 | 1.60 | 0.49 | 3 | 7.6 | 45 | 170.3 | 1.86 | 0.57 |
3/4 | 1.9 | 3 | 11.4 | 1.92 | 0.59 | 4 | 10.1 | 75 | 283.9 | 1.87 | 0.57 |
1 | 2.5 | 5 | 18.9 | 1.50 | 0.46 | 6 | 15.2 | 150 | 567.8 | 1.73 | 0.53 |
3.1 | 10 | 37.9 | 1.86 | 0.57 | 8 | 20.2 | 250 | 946.3 | 1.70 | 0.52 | |
3.8 | 10 | 37.9 | 1.41 | 0.43 | 10 | 25.4 | 450 | 1703.0 | 1.97 | 0.60 | |
2 | 5.0 | 20 | 75.7 | 1.80 | 0.55 | 12 | 30.5 | 500 | 1893.0 | 1.55 | 0.47 |
6.4 | 30 | 113.6 | 1.84 | 0.56 |
|
|
|
|
|
|
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED, DURING MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED SPRINKLER CONNECTION OR SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER PRESSURE CAN CAUSE SERIOUS INJURY.
1. Use a jockey pump only to fill the system at a velocity fill rate of less than 2' (0.61 m) per second.
CAUTION: Failure to comply with recommended fill rate will increase line pressure resulting in a water hammer effect that could damage sprinklers and piping components. See Warning above.
2.At all tees and greens use quick coupler keys with quick coupler valves to bleed air from the system lines during the filling process. For best results, do not compress air and then relieve it – bleed the air constantly while filling the system.
3.After water has filled all lines and all air is removed, remove the quick coupler keys.
Pilot Valve Operation (Electric Models Only) ________________________________________ | ||
The pilot valve controls the operation of the main valve located in the | Figure 3 | |
base of the sprinkler body. The main valve is operated by the release | ||
| ||
of water metered through the pilot valve when it is activated either | 100 PSI | |
manually at the sprinkler or by the irrigation system controller. | ||
(7.0 kg/cm2) | ||
The sprinkler operation mode is set using a Toro Selector Tool |
| |
(P/N |
| |
| ||
operation from the system controller. The "ON" mode opens the main | 80 PSI | |
valve for manual operation and "OFF" mode prevents the main valve | (5.6 kg/cm2) | |
from opening. |
| |
The pilot valve regulates the water pressure to the sprinkler nozzle. |
| |
Pressure regulation compensates for large variations within the |
| |
system and maintains a constant pressure for optimum sprinkler | 65 PSI | |
operation. The pilot valve is factory set to regulate one of four | (4.6 kg/cm2) | |
pressure levels: 50 psi (3.4 bar), 65 psi (4.5 bar), 80 psi (5.5 bar) or |
| |
100 PSI (6.9 bar). | 50 PSI (3.5 kg/cm2) | |
Change the pilot valve operating pressure by loosening the thumb |
| |
screw that secures the selector lever. Position the selector lever to |
| |
the desired operating pressure and |
|
4