Servicing Procedures ____________________________________________________
The DT series sprinklers are designed to provide the user
Servicing Sprinkler Mechanism
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED, DURING MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED SPRINKLER CONNECTION OR SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER PRESSURE CAN CAUSE SERIOUS INJURY.
Note: Refer to Figure 6 for the following procedure:
1.Insert hooked end of
2.Insert hooked end of
3.Use a 5/8" nut driver (P/N
4.Remove cap screw (1) and cap (3).
5.Grasp return spring (14) and riser (16) firmly and hold in place while removing nozzle base (4). Turn nozzle base assembly counterclockwise to remove.
6.Carefully release tension from return spring (14).
7.Remove spring and seal
8.Remove
9.Remove rock screen (19) turning it counterclockwise with edge of
10.Remove drive assembly (17) and stator (18) from riser assembly by carefully pressing on end of threaded shaft.
11.Using a 5/16" nut driver (P/N
12.Thoroughly clean and inspect all parts and replace as necessary. Reassemble in the reverse order. Note: During reassembly, ensure snap ring is correctly installed and fully seated in snap ring groove before operating sprinkler. See WARNING above..
Figure 6 |