Desa RGH3000, RGH5500 Engine OIL, Fuel, Engine Circuit Breaker, Receptacle Circuit Breaker

Page 7

OWNER’S MANUAL

GENERATOR

FEATURES

Continued

ENGINE CIRCUIT BREAKER

(Models RGH5500IE, RGH7500IE, and RGH11000IE)

This circuit breaker, or fuse, protects the battery charging circuit. A short circuit will trip the circuit breaker. The circuit breaker will also trip if you install battery wrong. Push circuit breaker button to reset. On Model RGH11000IE, the fuse is located inside of the Keyswitch box.

 

 

ON

 

OFF

START

Engine Circuit

ENGINE SW

 

BREAKER

 

CIRCUIT

Breaker Button

ON/push OFF

Figure 5 - Engine Circuit Breaker

RECEPTACLE CIRCUIT BREAKER

The circuit breakers protect the receptacles and alternator. Overloading generator will trip circuit breaker. A short circuit in item being powered will also trip breaker. If this occurs, unplug electrical load from recep- tacle. Let circuit breaker cool down. Push circuit breaker button to reset.

Electric motors need higher starting current. They require up to three-times their rated wattage to start. The starting current needed may be too high. This can cause nuisance circuit breaker tripping. To help prevent this, start electric motors first. Connect ad- ditional items to generator after starting motors. If this continues to happen, reduce the total generator load.

20

20

Normal

Tripped

Figure 6 - Receptacle Circuit Breaker Button

Note: High ambient temperature will cause nuisance tripping.

ENGINE OIL

We ship the generator without oil in the engine crankcase. You must add oil before starting engine. See engine owner’s manual for specific oil type.

CHECKING OIL LEVEL AND ADDING OIL

Follow steps below to check oil level. Make sure engine is level and stopped.

1.Remove dipstick (see Figure 7). Wipe dipstick clean.

2.Insert dipstick into oil filler neck. Do not screw it in. Oil level should be at top of filler neck. Oil should cover most of dipstick. For Model RGH11000IE only, the oil should be between the two dots on dipstick.

3.If level is low, fill to top of oil filler neck (see Figure 7). For Model RGH11000IE only, fill to top dot on dipstick. Only use oil recommended in engine owner’s manual.

Note: If oil level is too low, oil alert system will shutdown engine and prevent engine from restarting.

Oil Level

At Top Of

Filler Neck

Oil Dipstick

Figure 7 - Checking Oil Level (Model RGH5500 Shown)

FUEL

WARNING: Gasoline presents a hazard of fire or explosion. Gasoline is flammable. Its vapor is explosive.

Keep fuel out of children’s reach.

Refuel generator in a well- vented area. Do not fill fuel tank in the dark. Do not refuel while engine is running. Unhook all electrical loads and shut off engine before refueling.

Do not overfill fuel tank. Al- ways allow room for fuel to expand. If you overfill tank, fuel can overflow onto hot engine. This can cause fire or explo- sion. After refueling, tightly close fuel tank cap.

Do not spill fuel. Fuel or fuel vapor may ignite. If fuel spills, make sure area is dry before starting engine.

Never smoke in refueling area. Never allow open flames or sparks in area.

Store fuel in approved con- tainer. Store fuel in a well- vented area free of open flames or sparks.

Use clean, fresh, unleaded gasoline. Use gasoline with octane rating of 86 or higher. Service station gasoline pumps should dis- play the octane rating. Using gasoline with lower octane level could damage engine. Avoid getting dirt, dust, or water in fuel tank. Do not mix oil with gasoline.

See engine owner’s manual for more information.

104960

7

Image 7
Contents Portable Gasoline Generators Portable Gasoline Generators Safety InformationGfci Safety Information Product IdentificationVentilation High and LOW Temperature OperationGeneral Information UnpackingRGH3000PR RGH5500IE RGH7500IE SpecificationsRGH5500 RGH3000Electric Start Generator FeaturesFull Power Selector Switch OIL Alert SystemReceptacle Circuit Breaker Engine OILFuel Engine Circuit BreakerIf battery acid gets on your skin, wash with water BatteryInstalling Battery Cables to Engine Mounting Battery to GeneratorExtension Cords Generator GroundingAmpere AWG for Length Load Cord in Feet 100 150 Determining Electrical Load for Generator Standby Installation to Home or BuildingGeneral Information Power Cord and Plug RequirementsUsing Receptacle OperationStarting PrestartEngine SW OFF High Altitude Operation Adding Electrical Loads Disconnecting Electric LoadsStopping Engine Troubleshooting Maintenance and RepairsStorage Wiring Diagrams Electrical Component SpecificationsWiring Diagram, Model RGH7500IE Servicing the Engine Technical ServiceAccessories Replacement PartsParts Available not Shown Illustrated Parts ListFor Models RGH3000 and RGH3000PR Alternator Assembly KEY Part Number Description QTYPart Number for Model KEY Alternator AssemblyFor Models RGH5500 RGH5500IE, and RGH7500IEKEY Part Description Number QTY For Model RGH11000IE Alternator AssemblyNEC-5C For Models RGH3000 and RGH3000PR Roll CageWP-5C Portable Gasoline Generators Parts Available not Shown For Model RGH11000IE Fuel Tank and Roll Cage WP-4C WP-6CWLI-8 For Models RGH5500 RGH5500IE, and RGH7500IE Control Panel For Model RGH11000IE Control Panel Keep this Warranty Warranty Information

RGH3000, RGH5500IE, RGH5500, RGH3000PR specifications

Desa RGH3000PR, RGH5500, RGH5500IE, and RGH3000 represent a series of advanced heating solutions designed to deliver efficient warmth and comfort to a variety of spaces. Each model offers unique features and technologies that cater to different needs, whether for residential or commercial applications.

The Desa RGH3000PR is known for its powerful heating capability. Equipped with advanced flame technology, it delivers robust performance while maintaining energy efficiency. This model is particularly suited for larger areas, providing consistent warmth even in the coldest conditions. With a user-friendly thermostat control, users can easily adjust the temperature to their liking, enhancing overall comfort levels.

In contrast, the RGH5500 model shines with its sleek design and versatility. This unit features a sophisticated control system, which integrates smart technology, allowing users to monitor and adjust settings remotely via a mobile application. This connectivity enhances convenience, as homeowners can control their heating from anywhere, ensuring their space is warm upon arrival. Additionally, the RGH5500 includes safety features such as an automatic shut-off and overheat protection, making it a reliable choice for families.

The RGH5500IE takes the innovation a step further by incorporating energy-saving features without compromising on performance. Its EPA-certified technology ensures lower emissions while delivering maximum heat output. This model is particularly appealing for environmentally conscious consumers who wish to reduce their carbon footprint while still enjoying efficient heating. With multiple heating settings, it can easily adapt to different room sizes and heating needs.

Finally, the RGH3000 offers a compact solution perfect for smaller spaces. Despite its size, it packs a powerful heating punch and utilizes innovative radiant heat technology for quick warmth distribution. Its portability makes it ideal for various applications, from personal workshops to intimate living spaces. Moreover, the RGH3000 is built with durable materials designed to withstand extensive use, ensuring longevity.

In conclusion, the Desa RGH series—comprising the RGH3000PR, RGH5500, RGH5500IE, and RGH3000—delivers a range of heating solutions for diverse environments. Each model showcases impressive features, state-of-the-art technology, and exceptional performance, making them reliable choices for anyone seeking efficient and effective heating solutions. Whether it's enhancing home comfort or providing reliable warmth in commercial settings, the Desa RGH series stands out for its commitment to quality and innovation.