Desa PGH7500IE, PGH1100IE installation manual Operation, General Information, Using Receptacle

Page 11

OWNER’S MANUAL

OPERATION

GENERAL INFORMATION

This generator is not large enough to power your entire home. Do not connect generator to any existing electrical circuits. Plug items directly into generator receptacles. Do not exceed amperage rating of receptacles. Only use grounded cords.

DANGER: Use only in well- vented areas. Make sure area has plenty of free-moving, fresh, out- side air. Never run generator in an enclosed or confined area. Never run generator inside occu- pied building. Engine exhaust contains poisonous carbon mon- oxide gas. Overexposure will cause loss of consciousness and will lead to death.

DANGER: Never connect gen- erator to any existing electrical circuits. The generator output will back-feed into the utility power line. This may electrocute a power company line repair person. Also, if generator is powering electri- cal circuits, the chance of an elec- trical fire exists.

Note: We supply the engine Owner’s Manual with generator. Refer to that manual for questions concerning engine operation.

USING RECEPTACLE

Note: Do not exceed amperage rating of receptacles. Exceeding rating will trip re- ceptacle circuit breaker.

Use receptacles properly. Improper use could damage generator. Use only grounded ex- tension cords. Power only grounded or double-insulated items. Do not overload receptacles. Both generators have the fol- lowing receptacles (see Figure 14):

120V, 15-amp GFCI duplex receptacle

120V, 30-amp twist-lock receptacle

120/240V, 20 or 30-amp twist-lock receptacle

120V, 15-amp duplex receptacle

Model PGH11000IE also has a 120/240V, 50-amp receptacle (see Figure 14).

120V, 15-Amp GFCI Duplex

 

 

 

120V, 15-Amp Duplex

 

 

120/240V, 20 or 30-

120

VOLTS

Amp Twist-Lock

 

 

RESET

 

 

 

TEST

 

 

 

 

120/240

VOLTS

 

 

ENM

 

 

00000005

 

 

 

HOURS

RESET

 

 

1/10

120V, 30-Amp

 

RESET

 

 

Twist-Lock

RESET

240

VOLTS

 

 

RESET

 

RESET

 

 

 

 

RESET

120/240V, 50-Amp

(Model PGH11000IE only)

Figure 14 - Receptacle Locations

POWER CORD AND PLUG REQUIREMENTS

120V, 30-amp twist-lock receptacle

NEMA L5-30P plug

Three-wire, 30-amp cord

120/240V, 20 or 30-amp twist-lock receptacle

NEMA L14-20P (20-amp) or L14-30P (30-amp) plug

Four-wire, 20-amp or 30-amp cord

120/240V, 50-amp receptacle

NEMA L14-50P

Four-wire, 50-amp cord

120/240 Volt

 

 

 

 

20 Amp

 

Neutral

 

 

 

 

 

 

120V

120V

 

Ground

X

 

w

L14-20P

Y

X

(Green)

(Hot)

 

G

Plug

 

 

Ground

 

Y

W

 

 

 

(Neutral)

 

 

 

(Hot)

 

 

 

 

 

 

 

Figure 15 - Cord and Plug Configurations

Continued

106746

11

Image 11
Contents Portable Gasoline Generators Portable Gasoline Generators Safety InformationGfci Product IdentificationVentilation High and LOW Temperature OperationGeneral Information UnpackingPGH7500IE SpecificationsElectric Start Generator FeaturesOIL Alert System Engine Circuit BreakerChecking OIL Level and Adding OIL BatteryEngine OIL FuelMounting Battery to Generator Installing Battery Cables to EngineExtension Cords Standby Installation to Home or BuildingGenerator Grounding Determining Electrical Load for Generator Chart 1 Typical Electric Appliance WattagesGeneral Information Using ReceptaclePower Cord and Plug Requirements OperationStarting PrestartStopping Engine Disconnecting ElectricHigh Altitude Operation Adding Electrical Loads Storage Maintenance and RepairsTroubleshooting Wiring Diagrams Electrical Component SpecificationsFor Model PGH7500IE Alternator Assembly Illustrated Parts ListWLE-5 For Model PGH11000IE Alternator AssemblyFor Model PGH7500IE Fuel Tank and Roll Cage Parts Available not Shown For Model PGH11000IE Fuel Tank and Roll Cage Not shown For Model PGH7500IE Control Panel For Model PGH11000IE Control Panel Parts Centrals Technical ServiceReplacement Parts Servicing the Engine106746 International Warranty Information