Desa PGH7500IE, PGH1100IE Installing Battery Cables to Engine, Mounting Battery to Generator

Page 8

ä

PORTABLE GASOLINE GENERATORS

BATTERY

Continued

Always wear safety glasses when working with battery. Make sure battery terminals are clean. Make sure cable connections are tight.

Always shut down engine before removing or attaching battery cables. Always remove the negative (–) cable first. Always attach negative (–) cable last.

INSTALLING BATTERY CABLES TO ENGINE

1.Attach the red, positive (+) battery cable to the starter solenoid on engine (see Figure 7). The starter solenoid is located directly above the starter on Model PGH11000IE. This cable is fac- tory installed.

CAUTION: Do not over tighten positive terminal on starter sole- noid. Positive terminal could ro- tate and cut into negative termi- nal, causing a short.

2.Attach the black, negative (–) battery cable to the engine block. Use the bolt, nut, and two washers provided with the battery cables. Use long mounting hole on opposite side of engine from starter solenoid. Attach cable as shown in Figure 8.

Starter

Solenoid

Red, Positive (+)

Battery Cable

Figure 7 - Connecting Red, Positive (+) Battery Cable to Engine Starter Solenoid (Model PGH7500IE Shown)

Black,

Negative (–)

Battery Cable

Figure 8 - Connecting Black, Negative (-) Battery Cable to Engine Block (Model PGH7500IE Shown)

MOUNTING BATTERY TO GENERATOR

1.Secure battery to generator by battery hold-down system. This system consists of the battery mounting bracket, hook bolts, and nut (see Figure 9).

Note: Model PGH11000IE battery is located on opposite side as shown (see Figure 10).

2.Locate the red, positive (+) battery cable from starter solenoid. Connect it to the positive (+) battery terminal (see Figures 11 and 12).

3.Locate the black, negative (–) battery cable attached to engine block. Connect it to the negative (–) battery terminal (see Figures 11 and 12).

4.Check battery before starting engine. Make sure fluid levels are full. Make sure battery is charged.

See engine Owner’s Manual for more information.

Battery

Mounting

Bracket

Nut

120

 

ONLY

 

 

120

 

240V

ENM

Battery

00000005

 

Hook

Bolt

Nut

Battery

 

Battery

Hook

Mounting

Bolt

Bracket

Figure 10 - Battery Hold-Down System (Model PGH11000IE Shown)

FULL

POWER

TO ENGINE

120

 

BLOCK

ONLY

 

 

 

120

 

 

240V

ENM

 

HOURS00000005

 

 

1/10

 

TO STARTER

SOLENOID

Figure 11 - Connecting Positive and Negative Cables to Battery

(Model PGH7500IE Shown)

TO

STARTER

SOLENOID

TO

ENGINE

BLOCK

Figure 12 - Connecting Positive and Negative Cables to Battery

(Model PGH11000IE Shown)

Figure 9 - Battery Hold-Down System (Model PGH7500IE Shown)

8

106746

Image 8
Contents Portable Gasoline Generators Safety Information Portable Gasoline GeneratorsProduct Identification GfciHigh and LOW Temperature Operation General InformationUnpacking VentilationSpecifications PGH7500IEGenerator Features OIL Alert SystemEngine Circuit Breaker Electric StartBattery Engine OILFuel Checking OIL Level and Adding OILInstalling Battery Cables to Engine Mounting Battery to GeneratorExtension Cords Standby Installation to Home or BuildingGenerator Grounding Chart 1 Typical Electric Appliance Wattages Determining Electrical Load for GeneratorUsing Receptacle Power Cord and Plug RequirementsOperation General InformationPrestart StartingStopping Engine Disconnecting ElectricHigh Altitude Operation Adding Electrical Loads Storage Maintenance and RepairsTroubleshooting Electrical Component Specifications Wiring DiagramsIllustrated Parts List For Model PGH7500IE Alternator AssemblyFor Model PGH11000IE Alternator Assembly WLE-5For Model PGH7500IE Fuel Tank and Roll Cage Parts Available not Shown For Model PGH11000IE Fuel Tank and Roll Cage Not shown For Model PGH7500IE Control Panel For Model PGH11000IE Control Panel Technical Service Replacement PartsServicing the Engine Parts Centrals106746 Warranty Information International