OPERATION
Continued
STOPPING ENGINE
IMPORTANT: The engine speed is preset. The throttle is locked in preset posi- tion. Do not adjust throttle.
Follow the steps below to stop engine.
1.Remove all electrical loads from generator (see Disconnecting Electrical Loads, page 22). Remove electrical loads one at a time.
2.Let engine run for two or three minutes after removing electrical loads. This lets engine cool slightly.
3.Turn engine switch to the OFF position (see Figure 19).
4.Turn fuel valve lever off. Do this by moving valve lever fully to the left (see Figure 20).
ENGINE SW ON
OFF
HONDA
ON
OFF START
Engine Switch For All | ENGINE SW |
Models Except MGH7000 | CIRCUIT |
| BREAKER |
| ON/push OFF |
| Engine Switch For |
| Model MGH7000 |
Figure 19 - Engine Switch In OFF Position
Fuel Valve Lever
(Off Position)
Figure 20 - Fuel Valve Lever Off
23