Powermate PM0495501.17 manual Major Generator Features, Control Panel

Page 2

MAJOR GENERATOR FEATURES

*11 HP Honda OHV engine

*Cast-iron cylinder sleeves

*Low oil sensor

*Receptacles on control panel

*Voltmeter and Hour meter on panel

*Idle control

*Automatic voltage regulator (AVR)

*Battery charger

*5.6 gallon metal fuel tank

*Spark arrester

*Portability Kit

CONTROL PANEL

A.120 V, 20 Ampere Duplex Receptacle

This duplex is split so that 20 amps of current may be

drawn from each half of the receptacle. However, total power drawn must be kept within nameplate ratings. These receptacles may be used along with the twistlock receptacle provided the generator is not overloaded.

B. 120/240 V, 30 Ampere Twistlock Receptacle

A maximum of 30 amps may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. However, current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings.

C. Idle Control Switch

Some models are equipped with an idle control switch. (See Idle Control).

D. Circuit Breakers

The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE:

Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.

E.Hour Meter

An hour meter is provided to keep track of run time of the

unit. This may be used to track maintenance schedules.

F.Voltmeter

Provides visual indication of generator output voltage from

0-300 volts.

G. Battery Charger

NOT RECOMMENDED FOR USE WITH GEL PACK, SEALED OR SMALL (MOTORCYCLE) BATTERIES.

These generators contain an additional circuit used for battery charging purposes. A double binding post is provided on the control panel. The battery charger on this generator is referred to as an unregulated taper charger - the most widely used in the market today. The amount of current flowing will depend on the charging voltage and battery's state of charge. As the on-charge output current to the battery decreases, the output current to the battery increases and nearly becomes constant. Taper chargers are intended to be used with the provision that they will be disconnected from the battery after a maximum time on charge. Normally a period of 30 to 120 minutes is sufficient to recharge a weak battery. The charge level of the battery should be checked periodically.

CAUTION: This battery charging system is intended to recharge weak batteries, not to "boost start" vehicles. Do not overcharge battery or leave battery unattended.

Note: When the battery charger circuit is in use, the AC capacity is reduced by 180 watts. Make sure the combined load is within the rated limits.

Before charging a storage battery, check the electrolyte fluid level in all the cells. Add distilled water to each cell, if necessary, to bring the level back up to the manufacturer's required level.

WARNING: Storage batteries give off EXPLOSIVE hydrogen gas while charging. Do not allow smoking, open flames,sparks, or spark producing equipment in the area while charging.

Use cables approved for battery charging. Connect a red clip to the positive terminal of the battery. Connect a black clip to the negative terminal of the battery. Connect the other end of the clip wire to the corresponding black(-) and red (+)binding posts on the generator panel. After the battery is fully charged, remove the battery charging cable from the generator and then disconnect from the battery posts.

WARNING: Battery electrolyte fluid is comprised of sulfuric acid that can be very dangerous and cause severe burns. Do not allow this fluid to contact eyes, skin, clothing, etc. If contact or spillage does occur, flush the area with water immediately.

WARNING: Do not continue to charge a battery that becomes hot or is fully charged.

DC CIRCUIT BREAKER: The maximum current available from the battery charger circuit is 15 amps. An automatic DC circuit breaker has been provided to protect the circuit from overloads and assure that the battery gets recharged. If an overload occurs, the circuit breaker will trip. After it cools, it will automatically reset itself. The battery's maximum rate of charge will eventually reduce to less than 15 amps and then to zero as the battery approaches a 100 percent state of charge.

2

English

Image 2
Contents PM0495501.17 Major Generator Features Control PanelProblem Possible Cause Idle Control Trouble ShootingHOW to Obtain Warranty Performance SolutionTableau DE Commande Caractéristiques Principales DE LA GénératriceProbleme Cause Possible Correction Fonctionnement DE LA Commande DU RalentiDépannage DE LA Commande DU Ralenti Garantie Limitée NON Valide EN Mexique Panel DE Control Características DE Generadores MayoresDeteccion DE Fallos DE Control EN Vacio Problema Causa Posible CorrecciónFuncionamiento DE Control EN Vacio Garantia Limitada No ES Valida EN Mexico Parts Drawing / DES Pièces / Repuestos Parts List / Liste DES Pièces / Lista DE Repuestos Part Description Descripción QTYAirport Road Box Kearney, NE Fax

PM0495501.17 specifications

The Powermate PM0495501.17 is a versatile and robust generator designed to meet the needs of both residential and commercial users. This model offers a combination of power, portability, and reliability, making it an essential tool for various applications such as emergency backup, outdoor activities, and job site power needs.

One of the prominent features of the PM0495501.17 is its powerful 4-stroke engine, which provides a substantial output of up to 4,000 watts of starting power and 3,500 watts of running power. This ample wattage ensures that it can support multiple appliances simultaneously, making it ideal for powering essential items like refrigerators, lights, and HVAC systems during outages.

The PM0495501.17 also includes a user-friendly control panel that features a voltmeter and multiple outlets. This design allows users to easily monitor and manage power consumption. The generator is equipped with a variety of outlet options, including standard 120V household outlets and a 12V DC outlet for battery charging, making it versatile enough for different power requirements.

Portability is another highlight of the Powermate PM0495501.17, as it incorporates a sturdy wheel kit and foldable handle, allowing for easy transport and mobility. Weighing approximately 90 pounds, it strikes a balance between being robust and manageable. This lightweight design is a benefit for users who may need to move the generator to various locations.

Safety is paramount when dealing with generators, and the PM0495501.17 is equipped with essential safety features. It includes low oil shutdown technology, which automatically turns off the generator when the oil level is too low, preventing engine damage. Additionally, the unit has overload protection to avoid damage from excessive loads.

The design of the Powermate PM0495501.17 is also complemented by an efficient fuel system. It operates on gasoline and has a fuel tank capacity of 4 gallons, which allows for extended run times of up to 12 hours at half load. This efficiency translates to less frequent refueling during extended power outages or outdoor events.

In summary, the Powermate PM0495501.17 is an impressive generator that combines power, portability, and safety features. With its robust engine, user-friendly control panel, and safety technologies, it serves a wide range of applications and is a reliable companion for both home and work environments. Whether you need backup power during an outage or require a source of electricity for outdoor activities, the PM0495501.17 is a reliable choice.