Crown Audio ce 4000 operation manual Operation, Setup, CE 4000 Power Amplifier, page

Page 10
4 Operation

CE 4000 Power Amplifier

3 Setup

4 Operation

3.7 Connect to AC Mains

Connect your amplifi er to the AC mains power source (power outlet) with the supplied AC power cordset. First, connect the IEC end of the cordset to the IEC connector on the amplifi er; then, plug the other end of the cordset to the AC mains.

WARNING: The third prong of this con- nector (ground) is an important safety feature. Do not attempt to disable this ground connection by using an adapter or other methods.

Amplifi ers don’t create energy. The AC mains voltage and current must be suffi cient to deliver the power you expect. You must operate your amplifi er from an AC mains power source with not more than 10% variation above or below the amplifi er’s specifi ed line voltage and within the specfi ed frequency requirements (indicated on the amplifi er’s back panel label). If you are unsure of the output voltage of your AC mains, please consult your electrician.

3.8 Startup Procedure

Use the following procedure when fi rst turning on your amplifi er:

1. Turn down the level of your audio source.

2. Turn down the level controls of the ampli- fi er.

3. Turn on the “Power” switch. The Power indicator should glow.

4. Turn up the level of your audio source to an optimum level.

5. Turn up the Level controls on the ampli- fi er until the desired loudness or power level is achieved.

6. Turn down the level of your audio source to its normal range.

If you ever need to make any wiring or instal- lation changes, don’t forget to disconnect the power cord.

For help with determining your system’s opti- mum gain structure (signal levels) please refer to the Crown Amplifi er Application Guide, available online at www.crownaudio.com.

4.1 Precautions

Your amplifi er is protected from internal and external faults, but you should still take the fol- lowing precautions for optimum performance and safety:

1.Before use, your amplifi er fi rst must be confi gured for proper operation, includ- ing input and output wiring hookup.

Improper wiring can result in serious operating diffi culties. For information on wiring and confi guration, please consult the Setup section of this manual or, for advanced setup tech- niques, consult Crown’s Amplifier Application Guide available online at www.crownaudio.com.

2.Use care when making connections, selecting signal sources and controlling the output level. The load you save may be your own!

3.Do not short the ground lead of an output cable to the input signal ground. This may form a ground loop and cause oscillations.

4.Never connect the output to a power supply, battery or power main. Electrical shock may result.

5.Tampering with the circuitry, or making unauthorized circuit changes may be hazardous and invalidates all agency listings.

6.Do not operate the amplifi er with the red Clip LEDs constantly fl ashing.

7.Do not overdrive the mixer, which will cause clipped signal to be sent to the amplifi er. Such signals will be repro- duced with extreme accuracy, and loud- speaker damage may result.

8.Do not operate the amplifi er with less than the rated load impedance. Due to the amplifi er’s output protection, such a confi guration may result in premature clipping and speaker damage.

Remember: Crown is not liable for damage that results from overdriving other system components.

page 10

Operation Manual

Image 10
Contents CE Series Some models may be exported under the name AmcronCE 4000 Power Amplifier Important Safety Instructionspage page DECLARATION OF CONFORMITYCE 4000 Power Amplifier CE 4000 Power Amplifier Table of Contentspage CE 4000 Power Amplifier 2 How to Use This Manual1 Welcome 1.1 Features3.2 Install Your Amplifier 3 SetupCE 4000 Power Amplifier Figure 3.2 Airflow Figure 3.1 Dimensions3.4 Choose Input Wire 3 SetupCE 4000 Power Amplifier and Connectors3.5Choose Output Wire and Connectors 3 SetupCE 4000 Power Amplifier Figure 3.5 Speakon Output Connector Wiring3.6.2 How to Parallel the Inputs 3 SetupCE 4000 Power Amplifier pageCE 4000 Power Amplifier 4 Operation3 Setup pageC.Power Indicator CE 4000 Power AmplifierA.Power Switch D.Signal IndicatorFigure 4.2 Back Panel Controls and Connectors CE 4000 Power Amplifier4.3Back Panel Controls and Connectors 4 Operation5.1.2 Fault 5 Advanced Features and OptionsCE 4000 Power Amplifier 5.2.2Switching Power Supply with PFCSwitch CE 4000 Power Amplifier5.3 Other Features 5.3.2 Neutrik Speakon WiringCONDITION Normal operation 6 TroubleshootingCONDITION No power to the amplifier CONDITION Distorted soundPerformance Minimum Guaranteed Power watts7 Specifications CE 4000 Power Amplifier7 Specifications ConstructionCE 4000 Power Amplifier page574-294-8124 Factory Service 8 ServiceCrown Factory Service 574-294-8301 Technical SupportCE 4000 Power Amplifier 9 WarrantyYEAR SUMMARY OF WARRANTYCE 4000 Power Amplifier 3 YEAR9 Warranty HOW TO OBTAIN WARRANTY SERVICENATURE OF PROBLEM Crown Factory Service InformationCE 4000 Power Amplifier If warranty has expired, payment will beTHIS PAGE INTENTIONALLY LEFT BLANK CE 4000 Power Amplifierpage CE 4000 Power Amplifier page