Powermate PC0101100 Starting the Unit, PRE-START Preparation, Starting the Engine, Applying Load

Page 8

STARTING THE UNIT

Gasoline is very dangerous.

Serious injury or death may result from fire caused by gasoline contacting hot surfaces.

1.Do not fill fuel tank with engine running.

2.Do not spill fuel while refilling tank.

3.Do not mix oil with gasoline.

4.Follow all instructions and warnings in the operator manual.

PRE-START PREPARATION

Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment.

This generator must not be operated without all factory installed heat shields in place. Failure to comply may cause the fuel tank to overheat and result in personal injury from fire.

STARTING THE ENGINE

1.Check oil level and fuel.

2.Disconnect all electrical loads from the unit.

3.Open fuel shut off valve.

4.Adjust choke as necessary.

5.Set the engine switch to the “ON" position.

6.Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke. On electric start models, turn the key switch to “START”. Release key switch after the engine starts.

Allow generator to run at no load for five minutes upon each initial start-up to permit engine and generator to stabilize.

Provide adequate ventilation for toxic exhaust gases and cooling air flow.

Do not start or run the generator in an enclosed area, even if door or windows are open.

Engines give off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

APPLYING LOAD

This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Readjusting will void warranty.

When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.

Do not apply heavy electrical load during break-in period (the first two to three hours of operations).

SHUTTING THE GENERATOR OFF

1.Remove entire electrical load.

2.Let the engine run for two minutes without load.

3.Move the engine switch to the “OFF” position. (Turn the key switch to “OFF” on the electric start models).

4.Do not leave the generator until it has completely stopped.

5.Close the fuel shut off valve if the engine is to be put in storage or transported.

6.If a cover is used, do not install until unit has cooled.

English

 

8

 

Customer Hotline 1-800-445-1805

 

 

 

 

 

Image 8
Contents Stop AltoIndice Table of ContentsTable DES Matieres Safety and Operation Rules KW = 1,000 watts Spark ArresterDetermining Total Wattage Installation Operating VoltageBefore Operation Grounding the GeneratorLubrication FuelGenerator Features DI HStarting the Unit PRE-START PreparationStarting the Engine Applying LoadPeriodic Maintenance MaintenanceService and Storage Infrequent ServiceExciting the Generator Heat ShieldEngine Troubleshooting Engine Specifications Service Information Limited Warranty Powermate Corporation Airport Road Box Kearney, NEVoire la mort Règles D’OPÉRATION ET DE SécuritéPARE-ÉTINCELLES Détermination DE LA Puissance Totale NécessaireVérifier LA Tension Avant DE Mettre EN Marche Mise EN Place DE LappareilLubrification CarburantDisjoncteurs Tableau de commande Prise de 120 V, 20 aCaractéristiques DU Groupe Electrogene Demarrage DE Lappareil Préparatifs AU DémarrageBranchement DES Appareils Démarrage DU MoteurEntretien Périodique EntretienLA Bougie D’ALLUMAGE LE Type D’HUILEUsage ET Entreposage Depannage DU Moteur Caracteristiques DU Moteur Garantie Limitée Service ClienteleCommande DE Pièces DE Rechange Reglas DE Seguridad Y DE Funcionamiento SeguridadApagachispas Como Determinar EL Vataje TotalInstalacion EL Requerimiento DE VoltajeAntes DE LA Operacion Puesta a Tierra DEL GeneradorLubricacion CombustibleInterruptor Caracteristicas DEL GeneradorPanel de control Receptáculo de 120 voltios, 20 amperes Arranque DEL Unidad Preparacion Antes DE ArrancarArranque DEL Motor Como Aplicar UNA CargaMantenimiento Periódico MantenimientoBujia Tipo DE AceiteServicio Y Almacenamiento Excitacion DEL GeneradorEscudo DE Calor Servicio Poco FrecuenteDeteccion DE Fallos DEL Motor Especificaciones DEL Motor Servicio AL Cliente Garantía Limitada Como Pedir LOS RepuestosPC0101100 Part Description Descripción QTY Part Description Descripción Powermate Corporation