Generac 1654-0 owner manual Grounding, Operating Generator, Starting the Engine

Page 7

5500 Watt Heavy Duty Generator

GROUNDING THE

1. Turn the fuel valve to the “On” position (Figure 4).

GENERATOR

The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the unit. For that purpose, a GROUNDING WING NUT is provided on the generator end (Figure 3).

Figure 4 — Fuel Valve

Fuel Valve is shown in the On position

Figure 3 — Grounding Wing Nut

Grounding

Wing Nut

Generally, connecting a No. 12 AWG (American Wire Gauge) stranded copper wire to the grounding wing nut and to an earth–driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. Be careful to keep the grounding wire attached after connecting the stranded copper wire. However, local codes may vary widely. Consult with a local electrician for grounding requirements in your area.

Properly grounding the generator helps prevent electrical shock if a ground fault condition exists in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.

OPERATING THE

GENERATOR

CAUTION! Never start or stop the engine with electrical loads connected to the receptacles AND with the connected devices turned ON.

Starting the Engine

2.Place the choke lever in the “Choke” position (Figure 5).

Figure 5 — Choke Lever

3.Set the rocker switch to “On” position (Figure 6).

Figure 6 — Rocker Switch

4.Grasp the recoil handle and pull slowly until slight resistance is felt.Then pull rapidly to start engine.

5.Move choke lever to “Run” position a short distance at a time over several seconds in warm weather or minutes in cold weather. Let engine run smoothly before each change. Operate with choke in “Run” position.

NOTE: If engine still fails to start, see engine manual.This engine may be equipped with a low oil device.

Refer to the engine owner’s manual for more detailed starting instructions.

Disconnect all electrical loads from the generator. Use the following start instruction steps by numerical order:

7

Image 7
Contents Parts Included* / Piezas Incluidas Equipment Description Safety RulesWear protective goggles, rubber apron, and rubber gloves Install Wheel KIT Carton ContentsRemove Generator from Carton To fill your engine with oil Before Starting EngineAdd Gasoline Add OilKnow Your Generator Starting the Engine GroundingGenerator Operating Generator120/240 Volt AC, 30 Amp, Locking Receptacle Connecting Electrical LoadsReceptacles Stopping the EngineExample Power ManagementDont Overload Your Generator CapacityGeneral Maintenance SpecificationsRecommendations Engine Storage Generator Storage StorageOther Storage Tips Problem Cause Solution TroubleshootingWatt Heavy Duty Generator Schematic Wiring Diagram Exploded View Main Unit Qty Description Parts List Main UnitWheel Exploded View and Parts List Wheel KITCircuit Breaker Exploded View and Parts List Control PanelPeligro Descripción DEL EquipoAdvertencia Instrucciones DE SeguridadPrecaución Contenido DE LA Caja Para Retirar EL Generador DE LA CajaInstale EL Juego DE Ruedas Agregar Aceite al Motor Antes DE Darle Arranque AL MotorAgregue Gasolina Conozca SU Generador Operando EL Generador Conexion a Tierra DEL GeneradorEncienda el Motor 120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad ReceptáculosConexion De Cargas Electricas Parado Del MotorCapacidad No Sobrecargue EL GeneradorControl de la Energía Recomendaciones Generales DE Mantenimiento EspecificacionesAlmacenamiento Notas Diagnositicos DE Averías Problemo Causa AccionGenerac Portable Products, LLC Jefferson,Wisconsin U.S.A Garantía LimitadaLimited Warranty

1654-0 specifications

The Generac 1654-0 is a high-performance portable generator designed for reliable power supply during outages, outdoor activities, or construction projects. One of its standout features is its robust engine, which provides ample wattage to run essential appliances and tools. With a starting wattage of around 16,000 watts and continual power of approximately 15,000 watts, the Generac 1654-0 can effortlessly support larger devices, including refrigerators, air conditioners, and power tools.

A defining characteristic of the 1654-0 is its advanced Generac OHV engine, which is built for durability and efficiency. This horizontal shaft engine features a durable design that offers consistent performance over time, ensuring you won't be left without power when you need it most. The generator is also designed with a heavy-duty steel frame, providing added stability and protection.

The Generac 1654-0 is equipped with a large-capacity fuel tank that can hold around 10 gallons of gasoline. This generous fuel capacity allows for extended run times, making it perfect for long events or power outages. Additionally, a fuel gauge is incorporated, allowing users to monitor fuel levels easily.

One of the key technologies used in the 1654-0 is its True Power Technology, which provides clean and stable energy. This technology is crucial for sensitive electronic devices as it minimizes harmonic distortion to less than 5%, protecting your equipment from potential damage.

Convenience features are also abundant in the Generac 1654-0. The generator includes multiple outlets, offering a variety of connection options for different devices. There are also circuit breakers for added protection, ensuring safe operation.

The unit is designed with user-friendly controls and an easy-to-read LCD display that shows runtime hours, wattage used, and maintenance alerts. These features make it simple to manage and monitor the generator.

Another notable aspect is the generator’s portability. With sturdy wheels and a fold-down handle, it can be easily maneuvered to wherever you need power. Coupled with a lightweight design, the Generac 1654-0 addresses both performance and portability, making it an excellent choice for a variety of power needs. Whether for emergency backup or recreational use, the Generac 1654-0 stands out as a reliable and efficient solution.