Generac 11400 manual Troubleshooting

Page 11

Generac Portable Products PP5000T Generator

TROUBLESHOOTING

Problem

 

Cause

 

Solution

 

 

Engine is running, but no AC

 

1. Circuit breaker is open.

 

1.

Reset circuit breaker.

output is available.

 

2. Poor connection or defective cord

 

2.

Check and repair.

 

 

 

set.

 

 

 

 

 

3.

Connected device is bad.

 

3.

Connect another device that is in

 

 

 

 

 

 

good condition.

 

 

4.

Fault in generator.

 

4.

Contact Generac service facility.

 

 

 

 

 

 

Engine runs good but bogs

 

1. Short circuit in a connected load.

 

1.

Disconnect shorted electrical load.

down when loads are

 

2. Generator is overloaded.

 

2.

See “Don’t Overload the Generator”

connected.

 

 

 

 

 

on page 9.

 

 

3.

Engine speed is too slow.

 

3.

Contact Tecumseh service facility.

 

 

4.

Shorted generator circuit.

 

4.

Contact Generac service facility.

 

 

 

 

 

 

Engine will not start; or starts

 

1. On/Off switch set to Off (o).

 

1.

Set switch to On ().

and runs rough.

 

2. Dirty air cleaner.

 

2.

Clean or replace air cleaner.

 

 

3.

Out of gasoline.

 

3.

Fill fuel tank.

 

 

4.

Stale gasoline.

 

4.

Drain gas tank and fill with fresh

 

 

 

 

 

 

fuel.

 

 

5.

Spark plug wire not connected to

 

5.

Connect wire to spark plug.

 

 

 

spark plug.

 

 

 

 

 

6.

Bad spark plug.

 

6.

Replace spark plug.

 

 

7.

Water in gasoline.

 

7.

Drain gas tank; fill with fresh fuel.

 

 

8.

Overchoking.

 

8.

Put choke lever to “no choke

 

 

 

 

 

 

position.

 

 

9.

Low oil level.

 

9.

Fill crankcase to proper level.

 

 

10. Excessively rich fuel mixture.

 

10. Contact Tecumseh service facility.

 

 

11. Intake valve stuck open or closed.

 

11. Contact Tecumseh service facility.

 

 

12. Engine has lost compression.

 

12. Contact Tecumseh service facility.

 

 

 

 

 

 

Engine shuts down during

 

1. Out of gasoline.

 

1.

Fill fuel tank.

operation.

 

2. Low oil level.

 

2.

Fill crankcase to proper level.

 

 

3.

Fault in engine.

 

3.

Contact Tecumseh service facility.

 

 

 

 

 

 

Engine lacks power.

 

1. Load is too high.

 

1.

See “Don’t Overload the Generator”

 

 

 

 

 

 

on page 9.

 

 

2.

Dirty air filter.

 

2.

Replace air filter.

 

 

3.

Engine needs to be serviced.

 

3.

Contact Tecumseh service facility.

 

 

 

 

 

 

Engine “hunts” or falters.

 

1. Choke is opened too soon.

 

1.

Move choke to halfway position till

 

 

 

 

 

 

engine runs smoothly.

 

 

2.

Carburetor is running too rich or

 

2.

Contact Tecumseh service facility.

 

 

 

too lean.

 

 

 

 

 

 

 

 

 

 

11

Image 11
Contents PP5000T Equipment Description ContentsSafety Rules Grounding Wing Nut Grounding GeneratorKnow Your Generator SpecificationsAdd Oil Wheel KIT InstallationBefore Starting Unit No Choke Operating GeneratorAdd Gasoline Starting the EngineStopping the Engine Connecting Electrical LoadsCold Weather Operation 120/240 Volt, 20 Amp Locking Receptacle ReceptaclesVolt, 20 Amp Duplex Receptacle Volt, 30 Amp Locking ReceptacleRunning Watts DON’T Overload the GeneratorStorage Instructions General Maintenance RecommendationsTroubleshooting Schematic & Wiring Diagram Qty Description Wheel KIT Exploded View & Parts ListUnit Exploded View Optional Items Available Accessories Not IllustratedCompany Limited Warranty for Portable Generators