Generac 5500XL manual Operating Generator, Starting the Engine, Connecting Electrical Loads

Page 6

Generac Portable Products 5500XL Extended Life Generator

OPERATING THE

GENERATOR

CAUTION! Never start or stop the unit with electrical loads connected to the receptacles AND with the connected devices turned ON.

Starting the Engine

DANGER! Never run engine indoors or in enclosed poorly ventilated areas. Engine exhaust contains carbon monoxide, an odorless and deadly gas.

WARNING! Temperature of muffler and nearby areas may exceed 150°F (65°C). Avoid these areas.

Unplug all electrical loads from unit’s receptacles before starting the engine.

Make sure the unit is in a level position.

Open the fuel shut–off valve (Figure 3).

Figure 3 — Fuel Valve In Open Position

Make sure the Idle Control switch is “Off”.

Place the Run/Stop switch in the “Run” position.

Place the choke lever in the “Full” choke position by sliding it to the left toward the valve cover in the direction indicated by the arrow (Figure 4).

Figure 4 — Choke Lever

Full” Choke

Position

Grasp starter grip and pull slowly until you feel slight resistance, then pull quickly. Do Not let handle “snap back” into engine.

When engine starts, move choke lever to “Run” position by sliding it all the way to the right (away from the valve cover and under the arrow).

NOTE: If engine fails to start after 3 pulls, move the choke lever to “Half” choke position and pull starter rope again 2 times.

NOTE: If the engine still fails to start, check for proper oil level in crankcase. Unit is equipped with a low oil shutdown system. See engine owner’s manual for information regarding the low oil shutdown system.

Connecting Electrical Loads

Let engine stabilize and warm up for a few minutes after starting.

Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hertz electrical loads.

Do Not connect 240 Volt loads to the 120 Volt receptacles.

Do Not connect 3-phase or 50 Hz loads to the generator.

DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload the Generator” on page 10.

6

Image 6
Contents 5500XL Safety Rules Equipment DescriptionGrounding Generator Never operate the generatorKnow Your Generator Volt DC, 10 Amp Receptacle Recharge aBefore Starting the Engine Add OilAdd Gasoline Connecting Electrical Loads Operating GeneratorStarting the Engine Operating Automatic Idle Control Battery Safety Charging a BatteryStopping the Engine To recharge 12 Volt batteries, proceed as followsCold Weather Operation Cord SETS/RECEPTACLESVolt AC, 15 Amp Receptacle Volt AC, 30 Amp Locking Receptacle 120/240 Volt AC, 30 Amp Locking ReceptacleWatts DON’T Overload the GeneratorRecreational/Home Uses Professional/Contractor UsesGeneral Maintenance Recommendations SpecificationsStorage Troubleshooting Exploded View and Parts List Control Panel Qty DescriptionElectrical Schematic Wiring Diagram Exploded View Unit Parts List Unit Optional Accessories Not IncludedItems Not Illustrated Limited Warranty Consumer Commercial

5500XL specifications

The Generac 5500XL is a robust portable generator designed to provide reliable and efficient power for various applications. Whether for home backup during outages, outdoor activities, or job sites, the 5500XL combines practicality and performance, making it a popular choice among consumers.

One of the standout features of the Generac 5500XL is its powerful 5,500-watt output, capable of running essential appliances and tools. This generator is equipped with a Generac 389cc OHVI engine, which is designed specifically for generator use, ensuring optimal performance, durability, and longevity. The engine is well-regarded for its ability to run smoothly for extended periods, thus providing users with peace of mind during power interruptions.

The 5500XL is designed with user convenience in mind. It features an easy-to-read LED display that provides vital information about power usage and operational status. The unit also boasts a reliable starting system, combining a manual pull start with an easy-start recoil mechanism, enabling quick and effortless ignition in various conditions.

Portability is another significant advantage of the Generac 5500XL. It is designed with a sturdy frame and high-quality wheels that allow for easy transportation across different terrains. The built-in handle is ergonomically designed, providing comfort during movement and ensuring stability when in use.

In terms of safety, the Generac 5500XL includes features like a low-oil shutdown, which automatically turns off the engine when oil levels are too low, protecting the engine from damage. Additionally, the generator is equipped with a circuit breaker that helps prevent overloads, ensuring safe operation at all times.

The generator also comes with multiple outlets, allowing users to connect various appliances and tools simultaneously. This versatility is particularly useful for construction sites, camping trips, and home use, where different power requirements must be met.

Finally, the 5500XL is built with durability in mind, featuring a tough, weather-resistant design that can withstand the elements. This makes it suitable for outdoor use, where exposure to rain or dust is a concern. Overall, the Generac 5500XL combines power, portability, and safety, making it an excellent choice for those in need of reliable portable energy solutions.