Carrier ASPB07-1SI owner manual Plan the locationof your generator.NOTEDo not place

Page 6

It will be necessaryto paya visit to your local municipaloffices to applyfor a buildingpermit. Buildingpermitsarenecessaryto ensure proper installation, safety and adherenceto all local building code specifications.The location and phonenumber can befoundin the governmentsectionof yourlocal phonebook.

Plan the locationof your generator.NOTE:Do not place the

generatordirectlyunder a window.Selectan area outsideof your homenearestyour incominggas service.

Arrangefor installation of rigid gas piping (per local code specifications)to the locationwhereyou intendto positionyour generator.Fuel pipingshould includea fuel shut-off valve.The termination of the rigid piping should be aligned with the generatorfuel inlet locatedat the rearof the compartment.

Clearanarea5-1/2feetby5feetminimumofgrassandvegetation to a depthof 5 inches.This includesthe distancethe generator shouldbesetawayfromanystructure(3feet)and6 inchesbeyond thewidthandlengthof thegeneratormountingpad(48"Lx24"W).

NOTE:Local codes may supercede these requirements.

. Layblack poly-filmto coverthe area.

6.Fill the areato groundlevelwith peagravelor crushedstone.

7.Placethe generator,which is attached to the mountingpad,on the areayouhavejust prepared.

8a, Drivean 8 ft. groundingrodinto the groundto grade.

8b. Attach oneend of the groundingstrap (No. 12 AWGstranded copperwire)to groundingrodandthe otherendto thegrounding lug (locatedat rearcornerof unit). Makesuregroundingrodand strap arenot exposedabovegroundlevel. (NEDcodeappliesto groundingmethod.)

NOTE:Generatormodeswitch should be placedin the "off"

position.Generator main line circuit breaker should be switchedto "off" or openposition.

9a, Makethe connectionbetweenthe rigid fuel piping and the generatorusing the suppliedthreadedflexiblefuel line. Theflex hoseshouldbestraight. Donot bendthe hosein place of using pipe elbows. Use a pipe sealant suitable for gaseousfuel connections.Checkconnectionsfor leaks by openingmanual fuel shut-off valve and swab or sprayconnectionswith soapy water. If a leakexiststhe areawill bubblewith the presenceof the soapywater.

9b. If a leak is located,shutoff fuel, anddisconnectflexiblepiping. Drythe threadedendsand reapplyanadequateamountof pipe sealant. Reconnectflexible fuel line, open fuel supply and recheckfor leaks.If leak still exists,repeatstep9b.

Image 6
Contents Installation Guide ListedTurn to the Expertg IllU Readthismanualthoroughly GeneralhazardElectricalhazard FirehazardsExplosionhazards Plan the locationof your generator.NOTEDo not place Screw KnockoutInstallation& OwnersManualpriorto testingthesystem Flashin theAutoor Manualmode

ASPB07-1SI specifications

The Carrier ASPB07-1SI is an advanced air conditioning unit designed to provide efficient cooling and heating solutions for residential and commercial spaces. This system is part of Carrier's commitment to innovation, energy efficiency, and user-friendly operation, making it a popular choice among consumers looking for performance and reliability.

One of the standout features of the ASPB07-1SI is its remarkable energy efficiency. With a high Seasonal Energy Efficiency Ratio (SEER) rating, this model helps to reduce electricity consumption while maintaining a comfortable indoor climate. This not only lowers energy bills for users but also minimizes the overall environmental impact, aligning with modern sustainability efforts.

The unit incorporates advanced inverter technology, which allows it to adjust its cooling capacity according to the current needs of the space. This results in quieter operation and enhanced comfort levels, as the unit can maintain the desired temperature without the frequent on-off cycling typical of traditional HVAC systems. Additionally, this technology helps in prolonging the life expectancy of the unit by reducing wear and tear.

Carrier has equipped the ASPB07-1SI with smart control features, including Wi-Fi connectivity that enables homeowners to manage their climate control system remotely through smartphones or smart home platforms. This convenience allows users to adjust settings, set schedules, and monitor energy consumption from anywhere, enhancing user experience and comfort.

The ASPB07-1SI also emphasizes air quality, featuring integrated air filtration that helps to reduce dust, allergens, and other airborne particles. This is particularly beneficial for individuals with respiratory issues, ensuring a healthier indoor environment.

Another characteristic worth mentioning is the unit's compact design, which makes it suitable for various spaces, even those with limited installation areas. Its aesthetic and contemporary appearance blends seamlessly into modern interiors.

In summary, the Carrier ASPB07-1SI stands out for its energy efficiency, advanced inverter technology, smart controls, air quality enhancement, and compact design. These features position it as a reliable and efficient choice for anyone seeking to improve their climate control systems while enjoying modern conveniences and energy savings.