Installation Guide
NXC-REL10 Relay Card, 10 Channels
NetLinx Control Cards and NetModules
NetLinx Control Cards can be installed in either the NXF CardFrame,
For detailed information on the cards, refer to the NetLinx CardFrame, Control Cards, and NetModules Instruction Manual. available
NO and NC
Pinouts and Functions:
NXC-REL10 Pinouts and Functions
Pin | Function | Pin | Function |
|
|
|
|
1 | Relay 1A | 11 | Relay 6A |
|
|
|
|
2 | Relay 1B | 12 | Relay 6B |
|
|
|
|
3 | Relay 2A | 13 | Relay 7A |
|
|
|
|
4 | Relay 2B | 14 | Relay 7B |
|
|
|
|
5 | Relay 3A | 15 | Relay 8A |
|
|
|
|
6 | Relay 3B | 16 | Relay 8B |
|
|
|
|
7 | Relay 4A | 17 | Relay 9A |
|
|
|
|
8 | Relay 4B | 18 | Relay 9B |
|
|
|
|
9 | Relay 5A | 19 | Relay 10A |
|
|
|
|
10 | Relay 5B | 20 | Relay 10B |
|
|
|
|
NO and NC
FIG. 1 NXC-REL10 Relay 10 Control Card
NXC-REL10 Specifications
The
NXC-REL10 (FG2020) Specifications
Power Requirements: | 260 mA @ 12 VDC (maximum) |
|
|
Operation: | Relays |
|
|
LEDs: | 10 red LEDs light to show ON status activity for each |
| relay. |
|
|
Wiring: | • Two |
| • Commoning strip (metal) |
|
|
DEVICE_ID: | $010a |
|
|
NXC-REL10 Channel Assignments:
Channels
NXC-REL10 Connections/Wiring:
The
The relay contacts are rated for a maximum of 1A @
Jumpers located on the Card allow you to select Normally Open (NO) or Normally Closed (NC) contact settings:
Normally open (NO) mode setting on jumper pins 1 and 2 (default).
Normally closed (NC) mode setting on jumper pins 2 and 3.
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s). |
| REV: C |
|
12/07
©2007 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com