Black & Decker VEC027BD Using the Electromate Plus AS a JUMP-STARTER, Jump-Starting Instructions

Page 5

VEC027BD_ManualEN_122805 12/28/05 2:37 PM Page 4

WARNING

Do not recharge for more than 5 to 6 hours maximum using the 12 volt DC method.

USING THE ELECTROMATE PLUS AS A JUMP-STARTER

WARNING

Before using this system to jump-start any vehicle read and understand all instructions, safety tips, warnings, cautions and first aid information provided in this manual and on the product labeling. Additional important information may also be provided by the vehicle’s battery system manufacturer.

CAUTION

To avoid possible damage that may shorten the unit’s working life, protect this unit from direct sunlight, direct heat and moisture.

This system is to be used ONLY on vehicles, garden tractors and gasoline-powered generators with 12 volt DC battery systems.

This system is NOT designed to be installed as a replacement for a vehicle battery.

WARNING

Connect or disconnect battery leads ONLY when AC or DC charging supply cord is disconnected.

Jump-Starting Instructions

This jump-starter is equipped with a manual safety switch that only allows jump-start energy to flow when proper connections are made to battery and frame.

Connect — RED clamp first, then BLACK clamp. Disconnect — BLACK clamp first, then RED clamp.

1.Turn OFF vehicle ignition and all accessories (radio, A/C, lights, cell phone, etc.). Place vehicle in “park” and set the emergency brake.

2.Make sure jump-start system’s ON/OFF power switch is turned to OFF.

3.Connect jumper cables to unit.

4.To jump-start a NEGATIVE GROUNDED SYSTEM (NEGATIVE battery terminal is connected to the chassis — the most common configuration), follow steps 4a and 4b, then proceed to step 6.

4a. Connect the POSITIVE (+) RED clamp to vehicle battery’s POSITIVE ungrounded post.

4b. Connect the NEGATIVE (–) BLACK clamp to the vehicle chassis or engine block away from the battery. Do not connect the clip to carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gauge metal part of the frame or engine block.

5.To jump-start a POSITIVE GROUNDED SYSTEM — In the rare event that the vehicle to be started has a POSITIVE Grounded System, POSITIVE battery terminal is connected to chassis, replace steps 4a and 4b above with steps 5a and 5b, then proceed to step 6.

5a. Connect NEGATIVE (–) BLACK clamp to vehicle battery’s NEGATIVE ungrounded post.

5b. Connect POSITIVE (+) RED clamp to the vehicle chassis or engine block away from the battery. Do not connect the clip to carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gauge metal part of the frame or engine block.

DO NOT TURN SAFETY SWITCH ON IF REVERSE POLARITY ALARM SOUNDS OR THE REVERSE POLARITY INDICATOR LIGHTS. REVERSE THE CLAMP CONNECTIONS.

6.After making proper connections, turn safety power switch to ON.

7.Start vehicle (do not turn key for longer than 5-6 seconds).

8.After vehicle starts, turn the safety power switch to off, remove clamps (disconnect the frame or engine clamp first, followed by the battery cable). Disconnect the cables from unit.

Notes: Always disconnect the engine or frame jumper clamp first; followed by the battery jumper clamp.

If engine fails to start, leave the ignition turned off and disconnect the NEGATIVE (–) clamp first, then the POSITIVE (+) clamp. Try again later — the engine may be flooded.

Recharge the Electromate Plus after each use.

USING THE ALTERNATOR CHECK FEATURE

1.Turn the safety switch to the OFF position.

2.Connect jumper cables to unit.

3.Connect to vehicle.

4.Start engine.

5.Turn vehicle accessories off.

6.A green LED indicates a good alternator. A red LED indicates a bad alternator.

USING THE 12 VOLT DC PORTABLE POWER SUPPLY

1.Flip open one of the 12 volt DC outlet covers on the DC Power Supply Panel.

2.Insert the 12 volt DC plug from the appliance into the outlet.

3.Turn on the appliance and operate normally.

DC Power Supply Panel

12 VOLT DC OUTLETS

AIR VENTS

CAUTION

DO NOT USE UNIT TO POWER APPLIANCES THAT DRAW MORE THAN 5 AMPS DC.

4

5

Image 5
Contents Electromate Plus Important Safety Instructions Table of Contents Viewing Battery Charge Status Protective FeaturesAC and DC CHARGING/RECHARGING Volt AC ChargingUsing the Alternator Check Feature Using the Electromate Plus AS a JUMP-STARTERUsing the 12 Volt DC Portable Power Supply DC Power Supply PanelUsing the Tire Inflator Using the 120 Volt AC Power SupplyUsing the Emergency Area Light Replacement Parts Care and MaintenanceFuse Replacement DC Accessory Adapter Inflating Products Without a Valve StemVolt DC Specifications SpecificationsAC Power Specifications Tire Inflator Specifications