Briggs & Stratton 30209 Specifications, General Maintenance Recommendations, Engine Maintenance

Page 12

5500W Portable Generator

SPECIFICATIONS

Maximum Surge Watts . . . . . . . . . . . . . . . . . .8,500 watts Continuous Wattage Capacity . . . . . . . . . . . .5,500 watts Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0 Rated Maximum Continuous AC Load Current:

At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .45.8 Amps At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . .22.9 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . . 7 U.S. gallons Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 157 lbs.

GENERAL MAINTENANCE RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a

damaged or defective generator.

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Engine Maintenance

See engine owner’s manual for instructions.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

CAUTION

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.

12

Image 12
Contents 030209 5500W Table of Contents Safety RulesEquipment Description When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Assembly Install Wheel KITCarton Contents Remove Generator From CartonWhen Adding Fuel Before Starting the EngineAdd Engine Oil Add FuelUsing the Generator Connecting to a Building’s Electrical SystemOperating Generator System GroundConnecting Electrical Loads ReceptaclesStopping the Engine 120/240 Volt AC, 30 Amp, Locking ReceptacleCold Weather Operation Volt AC, 20 Amp, Duplex ReceptaclesPower Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsEngine Maintenance Generator MaintenanceStorage Generator StorageEngine Storage Other Storage Tips Troubleshooting Problem Cause Correction5500W Portable Generator Schematic Wiring Diagram Exploded View Main Unit Exploded View Parts List DescriptionParts Not Illustrated Exploded View and Parts List Alternator StatorExploded View and Parts List Control Panel Exploded View and Parts List Wheel KIT WheelLimited Warranty Tabla DE Contenidos Descripción DEL EquipoInstrucciones DE Seguridad AdvertenciaPeligro Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Tapa del Depósito del Aceite Llene el motor con aceiteMontaje Instale EL Juego DE RuedasPara Retirar El Generador De La Caja Contenido de la CajaAntes DE Darle Arranque AL Motor Agregar Aceite al MotorAgregue Combustible Cuando Añada CombustibleUSO DEL Generador Operando EL Generador PrecauciónTierra del Sistema Conexión al Sistema Eléctrico de un EdificioReceptáculos Precaución Conexion De Cargas ElectricasParado Del Motor 120/240 Voltios AC, 30 Amp, Receptáculo de SeguridadOperación Durante UN Clima Frío Volt AC, 20 Amp, Receptáculos DoblesNo Sobrecargue Generador CapacidadControl de la Energía EjemploEspecificaciones Recomendaciones Generales DE MantenimientoMantenimiento del Motor Mantenimiento del GeneradorDiagnositicos DE Averías AlmacenamientoAlmacenando el Generador Almacenando el MotorGarantía Limitada