Baldor PC43RI, PC32RI manual Burn Installation

Page 8

Warning Statements Continued

Burn

WARNING: Parts of this generator are extremely hot during and after operation. To prevent severe burns, do not touch any part of the generator until you have first determined if the part is hot. Wear protective clothing and after use allow sufficient time for parts to cool before touching any part of the generator.

WARNING: Do not touch the hot exhaust parts or the high voltage spark plug or coil terminals of the engine. Although spark plug voltages are not normally lethal, a sudden involuntary jerk of the hand or body part caused by contact with high voltage or a hot surface can result in injury to yourself or others.

Installation

WARNING: Installation and servicing of batteries is to be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.

WARNING: Installation and repair procedures requires specialized skills with electrical generating equipment and small engine systems. Any person that installs or performs repairs must have these specialized skills to ensure that the generator set is safe to operate. Contact Baldor for installation or repairs.

WARNING: Be sure all wiring complies with the National Electrical Code (NEC) and all regional and local codes or CE Compliance. Improper wiring may cause a hazardous condition and exposure to electrical hazards can cause serious injury or death.

WARNING: Be sure the system is properly grounded before applying power. Do not apply AC power before you ensure that grounds are connected. Electrical shock can cause serious or fatal injury. NEC requires that the frame and exposed conductive surfaces (metal parts) be connected to an approved earth ground. Local codes may also require proper grounding of generator systems.

WARNING: Place protective covers over all rotating parts such as drive shaft, pulley, belt etc. Rotating parts cause extremely dangerous situations because they can catch loose clothing or extremities and cause serious or fatal injury.

WARNING: Unauthorized modification of a generator set may make the unit unsafe for operation or may impair the operation of the unit. Never start a generator set that has been modified or tampered with. Be sure that all covers and guards are properly installed and that the unit is safe before starting the engine. If you are unsure, contact Baldor before starting the engine.

WARNING: When moving the generator, use reasonable caution. Be careful where you place fingers and toes to prevent injury “Pinch Points”. Never try to lift a generator without a hoist or lift means because they are heavy and bodily injury may result.

WARNING: When transporting a generator secure the unit to prevent movement during transport.

WARNING: Never connect this generator to any buildings electrical system unless a licensed electrician has installed an approved transfer switch. The National Electrical Code (NEC) requires that connection of a generator to any electrical circuit normally powered by means of an electric utility must be connected by means of approved transfer switch equipment so as to isolate the electrical circuit from the utility distribution system when the generator is operating. Failure to isolate the electrical circuits by such means may result in injury or death to utility power workers due to backfeed of electrical energy onto the utility lines.

WARNING: Circuit overload protection must be provided in accordance with the National Electrical Code and local regulations.

WARNING: Check Ground Fault Circuit Interrupt (GFCI) receptacles monthly by using the “Test” and “Reset” buttons.

Continued on next page.

1-4 Product Safety Information

MN2403

Image 8
Contents PC32Ri and PC43Ri Portable Generator California Proposition 65 Warning Table of Contents Ii Table of Contents MN2403 Section Product Safety Information Read This Manual ThoroughlySymbols OperationOperation Warning Statements Burn Installation Maintenance Product Safety Information MN2403 Section General Information Limited WarrantyWarranty Period Generator Series Labor Parts General Information MN2403 Section Receiving & Installation StoragePhysical Location Frame Ground Connection Frame Ground Connection Engine OilPage Recommended Engine Oil and Battery Type Use of Electric Motor LoadsVoltage Drop in Extension Cords Voltage Drop in Electrical Extension CordsSection Operation Operator Control Panel ~ AC Output DC OutputShown With Left Cover Removed Connection Diagram Section Troubleshooting and Maintenance Check Air Cleaner Left side coverCheck Fuel Level Check Oil Level SE or higher grade SAE 10W−30 or SAE 10W−40 Left side coverClean/Adjust Spark Plug Left side cover Clean Spark ArresterCleaning Periodic Maintenance ScheduleProblems and Solutions Troubleshooting GuideService Engine Oil SE or higher grade SAE 10W−30 or SAE 10W−40Baldor District Offices California Proposition 65 Warning

PC32RI, PC43RI specifications

The Baldor PC32RI and PC43RI are a pair of robust and efficient industrial motors designed for demanding applications, particularly in the food and beverage industry, packaging, and other heavy-duty sectors. These motors are known for their reliability and high performance, making them ideal for environments that require continuous operation.

One of the main features of the Baldor PC32RI and PC43RI is their high efficiency. These motors are designed to meet or exceed the efficiency standards set by the National Electrical Manufacturers Association (NEMA). This efficiency translates to reduced energy consumption, which not only lowers operating costs but also contributes to a smaller carbon footprint. The motors are engineered to optimize performance while minimizing heat generation, enhancing their longevity and reducing maintenance needs.

Another significant characteristic of these motors is their advanced design, which incorporates innovative technologies. The PC32RI and PC43RI feature robust construction with high-quality materials that ensure durability and reliability under harsh conditions. They include an adjustable base, allowing for flexible mounting options, which is crucial for various installation needs. The motors also come with sealed bearings, enhancing their reliability by preventing contamination from dust and moisture in industrial settings.

The Baldor PC32RI and PC43RI motors also employ electronic controls that provide precision in operation. These controls allow for variable speed functionality, which is essential for applications requiring precise torque and speed adjustments. This flexibility is particularly beneficial in processes where load conditions frequently change. Furthermore, the integration of built-in safety features, such as over-temperature and overload protection, ensures that the motors operate within safe parameters, prolonging their service life and safeguarding connected equipment.

In addition to these technological advancements, the Baldor PC32RI and PC43RI are also designed to be user-friendly. The motors come with comprehensive documentation and support, making installation and troubleshooting straightforward for operators. Their compact design allows for easy integration into existing systems without requiring extensive modifications.

Overall, the Baldor PC32RI and PC43RI stand out in the market due to their combination of efficiency, durability, and advanced technology. These motors are perfect for businesses seeking reliable solutions to enhance their productivity and reduce operational costs. With a strong emphasis on innovation and performance, Baldor continues to set a standard in the industrial motor industry.