ELECTRICAL LOADS AND GUIDELINES
Your generator set is designed to power electrical apparatuses within the electrical power output limitations of the generator. Please note that any generator overload can cause serious problems/damage to your generator. Additionally, apparatuses with electrical motors can require higher wattage requirements at
WATTAGE REQUIREMENTS OF ALL POWERED APPARATUSES (INCLUDING
As a reference only, Table 1 below shows some general wattage requirements for several common electrical devices. This chart is intended as a guide only. The actual total wattage should be determined by referring to the actual labels on each of the powered electrical devices.
Table 1 GENERAL WATTAGE GUIDE
Item | Running Watts |
Air Conditioner (12000 Btu) (*) | 1750 |
Air Compressor (1/2 hp) (*) | 1400 |
Air Compressor (3/4 hp) (*) | 1800 |
Air Compressor (1 hp) (*) | 2000 |
Battery Charger (25A) | 600 |
Belt Sander (3” belt) | 1000 |
Circle Saw (6 ½”) | |
Coffee Maker | |
Edger (lawn) | 550 |
Furnace Fan (1/3 hp) (*) | 1200 |
Hot Plate (single) | 1500 |
Impact wrench | 600 |
Light Bulb | Bulb rated |
Nail Gun | 1200 |
Microwave | 750 |
Paint Sprayer (1/3 hp) (*) | 650 |
Paint Sprayer, | 175 |
Radio | |
Refrigerator (*) | 600 |
Table Saw (10”) (*) | 2000 |
Television | |
Weed Trimmer | 500 |
Note: (*) Items allow 2.5 times the listed wattage | |
for starting. |
|
GENERATOR DESIGNED
PERFORMANCE GUIDELINES
This electrical generator is designed to produce electrical energy for the purpose of powering lights, power tools, appliances and motor loads within the intended design constraints of the generator. The generator is designed to produce
Table 2 | PERFORMANCE SPECIFICATIONS | |||
SKU Number |
| Voltage | Cont. Watts | Surge Watts |
40814 |
| 120/240 VAC | 4400 Watts | 5000 Watts |
42723 |
| (Single Phase) | 37.5 Amps @ 120 VAC | 42 Amps @ 120 VAC |
42724 |
|
| 18.5 Amps @ 240 VAC | 21 Amps @ 240 VAC |
39461 |
| 120/240 VAC | 6100 Watts | 8000 Watts |
40423 |
| (Single Phase) | 51 Amps @ 120 VAC | 67 Amps @ 120 VAC |
42725 |
|
| 26 Amps @ 240 VAC | 33 Amps @ 240 VAC |
42726 |
|
|
|
|
39982 |
| 120/240 VAC | 9350 Watts | 10000 Watts |
42727 |
| (Single Phase) | 78 Amps @ 120 VAC | 83 Amps @ 120 VAC |
|
|
| 39 Amps @ 240 VAC | 41.5 Amps @ 240 VAC |
39984 |
| 120/240 VAC | 10500 Watts | 12000 Watts |
40827 |
| (Single Phase) | 88 Amps @ 120 VAC | 100 Amps @ 120 VAC |
42728 |
|
| 44 Amps @ 240 VAC | 50 Amps @ 240 VAC |
Table 3 Engine Type
SKU Number | Engine | HP |
40814 | Honda GX 270 | 9.0hp |
42723 | Honda GX 270 | 9.0hp |
42724 | Honda GX 270 | 9.0hp |
39461 | Honda GX 390 | 13.0hp |
40423 | Honda GX 390 | 13.0hp |
42725 | Honda GX 390 | 13.0hp |
42726 | Honda GX 390 | 13.0hp |
39982 | Vanguard | 16.0hp |
42727 | Vanguard | 16.0hp |
39984 | Vanguard | 18.0hp |
40827 | Honda GX 620 | 20.0hp |
42728 | Honda GX 620 | 20.0hp |
ENGINE LIMITATIONS ON GENERATOR
PERFORMANCE
Generator ratings assume 60°F (20C) and Sea Level. Operation of your generator at temperatures above 60°F (20C) or above Sea Level will result in lower electrical output. Electrical output must be derated 2% for each 9°F above 60°F and 3 ½ % for each 1000 feet above mean sea level.
7