Craftsman 580.327071 owner manual 120/240 VOLTS, 30 AMP Receptacle, VOLTS, 50 AMP Receptacle

Page 7

ASSEMBLY

NEUTRAL (N)

PURCHASEDi_-- 11A 3-WtRE CORD

120 VAC

HOT (H)

i

\

/--/-7/

GROUND (G)

FIGo 2

shock, However, local codes may vary widely Consult with a local electrician for grounding requirements in your area

CORD SETS AND CONNECTOR PLUGS 12o VOLTS DUPLEX RECEPTACLE

Use only high quality, well-insulated, extension cords with the 120-vott "duplex" type electrical receptacles,, All cord sets used should be rated 125 volts at 20 AC amps or

FIG. 3

4-Wire Cord Set

greater for most electrical devices Keep extension cords as short as possible, preferably less than I5 feet long to prevent voltage drop and wires from overheating

Y (Hot)

(Hot)

t20 VOLTS, 20 AND 30 AMP RECEPTACLES:

For the 120 volts, 20 amp locking type NEMA L5-20R receptacle, a well-insulated cord set wilh a NEMA L5-20P locking type connector plug must be properly connected to the receptacle and to the desired 120 volts, single phase, 60 Hz, AC load Cord sets should be rated 20 AC amperes at 125 votts (or greater) for most electrical devices (Fig 3)

°For 120 volts, 30 amp locking type NEMA L5-30R receptacle, a well-insulated cord set with a NEMA L5-30P locking type connector plug must be properly connected to the receptacle and the desired 120 volts, single phase, 60 Hz, AC load The cord set should be rated 30 AC amperes at 125 volts (or greater) for most electrical devices (Fig 3)

120/240 VOLTS, 30 AMP RECEPTACLE:

A t20/240 volts, 30 amp, locking type type mating connec-

tor plug (Fig 4) is required when using this receptacle A 4-wire cord set, rated 30 AC amperes at 250 voJts (or

greater), is required and must be connected to the plug and to the desired loads Order NEMA type L14-30P

/ ,_-/Grour}d

(Green)

FIGo 4

240 VOLTS, 50 AMP RECEPTACLE

This receptacle is rated 50 AC amperes at 250 volts You

need a 3-prong grounded connector plug with same rating to use with this outlet Although current capacity of outlet is rated at 50 amps, loads applied through this outlet should not exceed 333 amps or you will overload the generator,

Image 7 Contents
Hours AssemblyService and Adjustment Repair Parts Model noSafety Rules Displacement Rated Maximum Power Phase BatteryTable of Contents IIllmi Contents of Hardware PackGrounding the Generator AssemblyInstalling Wheel KIT To Remove Generator from CartonVOLTS, 50 AMP Receptacle 120/240 VOLTS, 30 AMP ReceptacleRlter Know Your GeneratorRecommended SAE Viscosity Grades Connecting Electrical LoadsBefore Starting Engine Add OilStopping the Engine Battery SafetyCharging a Battery OperationRunning Watts Watis Dont Overload the GeneratorWattage Reference GuideChanging OIL Generator MaintenanceTo Clean the Generator General RecommendationsChange OIL Filter Customer ResponsibilitiesCheck oil bevel YearlyReplace in-line ue!filter Engine Speed Service and AdjustmentsCarburetor Engine Performance Problems Cause Troubleshooting PointsCraftsman 8000 Watt Deluxe A-C Generator Wiring Diagram M6 Lock Washer 4 REQ Craftsman 8000 Watt Deluxe AC Generator Repair PartsBrush Holder Assembly 1 REQ DescriptionWasher Vibration Mounting 1 REQ Craftsman 8000 Watt Deluxe A-C Generator Repair PartsItem Part no Washer Wheel 2 REQDl,.m my N, u2573 Drml,ir No 819 851 SEARS, Roebuck and CO Craftsman Deluxe 8000 Watt A-C Generator Repair Parts580.327075 Hub Craftsman 8000 Watt A-C Generator Repair PartsPRODUCT-- Deluxe Portable Generator Model Number Lowing InformationPart Description