To start this generator:
1.Confirm that there are no electrical devices connected to this generator. Connected devices may increase the difficulty in starting the engine.
2.Confirm that this generator is properly grounded. (See “Ground the Generator” section of this manual.)
3.Turn the fuel valve to the “on” position as shown in Figure 4.
4.Move the choke lever to the “closed” position as shown in Figure 5.
5.Insert the key into the ignition.
6.Perform step 6a. for electric start if the battery has already been installed. Perform step 6b. for a manual start without battery.
6a. Turn the key to the “BATT START” position. Release the key when the generator starts.
6b. Turn the key to the “PULL START” position. Slowly pull on the recoil starter handle, shown in Figure 6, until a slight resistance is felt. Then pull briskly to start the engine. Gently return the cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back.
7.If the engine fails to start, repeat step 6. NOTE: After repeated attempts to start the engine, consult the troubleshooting guide before attempting again. If problems persist, call
8.Once the engine has started and runs for about a minute, move the choke lever approximately half way towards the “open” position. Wait an additional 30 seconds and then move the choke lever completely over to the “open” position.
9.Allow this generator to run for several minutes before connecting any electrical devices.
Figure 4 - Fuel Valve in the “on” position | Figure 5 - Choke Lever in the “closed” position. (Refer to the Generator |
| Components chart to find the location of the Choke Lever.) |
Figure 6 - Pull-cord for starting the engine.
Model | 15 |