PREPARING THE GENERATOR FOR USE
Using this Generator for the First-Time
STOP!
The following section describes the required steps for preparing this generator for the first use. Failure to correctly perform these steps can damage this generator and/or shorten its life. If still unsure about how to perform any of these steps after reading this section, call
If this generator is being used for the first time, the following few steps are required to prepare it for operation:
Step 1 - Add Oil
This generator requires engine oil to function. Engine oil is a major factor affecting engine performance and service life. When new from the package, this generator contains no oil in the engine crankcase. The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 38 fluid oz (1.13 L) for this ACDelco Model
Model | 1.2 / 38 / 1.13 |
Model | High Detergent Motor Oil, |
To add oil:
1.Confirm that this generator is on a level surface.
2.Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 1.
3.Using a funnel, add high detergent motor oil to fill the engine crankcase to the correct quantity as stated above.
4.Replace the oil filler/dipstick cap.
Figure 1 - Unscrewing the Oil Cap | Figure 2 - Adding Oil |
Model | 11 |