Commercial Snowblower
TROUBLESHOOTING
SYMPTOM | PROBABLE CAUSE |
| REMEDY |
D1 Nothing Works | Hydraulic Circuit Not Complete |
|
|
| 1. Hydraulic Valve not engaged | 1. | Engage valve to full detent |
| 2. 1 or more quick couplers not | 2. | Fully engage all couplers |
| completely engaged. |
|
|
| 3. Defective quick coupler | 3. | Replace defective quick couplers |
| 4. Hydraulic pump low on fluid | 4. | Top up fluid level |
D2 Auger Rotates | Hydraulic Circuit Reversed |
|
|
backwards, and | 1. Main valve is in reverse | 1. | Reverse valve direction or |
fan does not | 2. Quick couplers are connected | 2. Switch hose connections to | |
rotate | backwards. |
| the machine. |
D3 Fan turns too | 1. Inadequate hydraulic flow for | 1. Check the gpm of your | |
slow | this motor size. |
| system. |
| 2. Wrong motor for your system. | 2. Contact your dealer. | |
D4 Fan motor stalls | Valve #4 (Fig. 1) set too high |
| See MODULATING |
|
|
| ELEMENT SET UP |
D5 Auger motor | Valve #4 (Fig. 1) set too low |
| See MODULATING |
slows or stalls |
|
| ELEMENT SET UP |
too quickly |
|
|
|
D6 Fan & Auger work | Electrical Problem |
|
|
but chute controls | 1. Electrical connections to battery | 1. | Ensure that the clamps are |
do not work |
|
| making proper connection. |
properly | 2. Breaker is tripped. | 2. | Reset breaker. |
| 3. Connector from Sw to block not | 3. Ensure the connector is | |
| contacting. |
| fully engaged. Check for |
|
|
| broken wires. |
| 4. Connection to | 4. Check all items in D6 | |
| (Fig. #1) is not making |
|
|
| 5. Diodes in switchbox are defective. | 5. | Check for voltage through diodes |
| 6. Solenoid Valve Spool is stuck | 6. Replace #8a or 8b solenoid | |
|
|
| cartridge. |
D7 Chute controls do | 1. The | 1. | Back of the |
not work properly | #14a (Fig. #1) set too low. |
| till it rotates freely by hand. Then |
in |
|
| turn in till you feel it contacting the |
conditions. | 2. Electrical: Switch, harness, |
| spring. Then turn in 2 turns. |
| 2. | Check the | |
| connectors, coil 10a, diodes |
| #5 in Fig. #2 |
| 3. Polarity of the system is reversed. | 3. | Red Alligator clip must be |
|
|
| on the Positive Terminal |
| 4. Diodes in switchbox defective. | 4. | Replace defective diodes. |
| 5. Defective Coil #10a (Fig. #1) | 5. | Replace Coil. |
| 6. Defective Valve #6 (Fig. #1) | 6. | Replace Valve. |
D8 Chute Rotation | 1. See | 1. Same as | |
seems to lack | 2. Valve #14b or #14c set too low. | 2. | Back of the |
power to turn. |
|
| till it rotates freely by hand |
|
|
| then turn in till you feel it |
|
|
| contacting the spring. Then |
|
|
| turn in 2 turns. |
| 32 |
|
|