Pentair D.E. Cartridge Style Filter important safety instructions Clamp Installation

Page 12
Clamp Installation

6

Clamp Installation

These instructions MUST BE FOLLOWED EXACTLY to prevent the lid from blowing off during system restart or later operation.

1.Perform the following steps before working on any part of the circulating system, e.g., clamp, pump, filter, valve(s), etc.

a.Turn the pump off and shut off any automatic controls to ensure that the system is not inadvertently started during servicing.

b.Open the High Flow™ manual air relief valve until it snaps into the full open position (this only requires a quarter turn counter clockwise).

c.Wait until all pressure is relieved. Never attempt to assemble, disassemble or adjust the filter clamp while there is any pressure in the filter.

2.Be certain the o-ring is in position in the lower tank half. Press the filter lid over the lower tank half sandwiching the o-ring in between.

3.Holding the ends of the filter clamp apart, position the center segment of the filter clamp over both upper and lower tank flanges. Bring the ends of the filter clamp together, while inserting the T-bolt into the trunnion; see Figure 2.

4.Using Figure 2 as a guide — place washer (large I.D.) and the tension-indicating spring on the barrel nut. Place the second washer (small I.D.) on the T-bolt. Hand-tighten nut. Recheck filter clamp for proper seating on tank flanges.

5.Begin to tighten nut using a 7/8 in. wrench. Then tap around the outside of the filter clamp with a mallet (or similar tool) to ensure uniform loading and proper seating of the clamp. Continue tapping and tightening until the spring coils touch each other. Do not tighten beyond this point.

6.Follow the instructions in Section 4; on page 7, SYSTEM RESTART INSTRUCTIONS.

7.The spring coils should be checked at least once per month to ensure that they continue to touch each other, indicating that the clamp is under sufficient tension. If coils fail to touch, repeat Step 5 above.

Figure 2.

Quad D.E.™ Filter Installation and User’s Guide

Image 12
Contents D.E. Cartridge Style Filter Installation and Users GuideIMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS Quad D.ECustomer Service Web siteTable of Contents Quad D.E. Filter Installation and User’s GuideIMPORTANT SAFETY PRECAUTIONS Consumer Information and SafetyImportant Notice WARNING - THIS FILTER OPERATES UNDER HIGH PRESSUREIMPORTANT SAFETY PRECAUTIONS continued WARNING - Risk of electrical shock or electrocutionGeneral Installation Information Section Introduction Quad D.E. Cartridge Style Filter OverviewThe crystal clarity of D.E. with cartridge convenience The highest water clarity with the lowest amount of fussGeneral Features Additional FeaturesSection Installation Installing the Quad D.E. FilterGeneral Information, cont.’d WARNING - THIS FILTER OPERATES UNDER HIGH PRESSURESection Filter Operation General Filter InformationClamp Installation Section System Restart Instructions System Restart InstructionsPreparing Diatomite Coating the Filter Elements with Diatomaceous EarthSection Maintenance Cleaning the Quad D.E. Filter ManuallyCleaning your Filter using a System with a Separation Tank Replacing Filter Cartridge Style ElementsCleaning your Filter using a System with a Separation Tank, cont’d Cleaning Filter ElementsCleaning the Internal Air Bleed Tube Cleaning the High Flow Manual Air Relief ValveSection Troubleshooting Problems and Corrective ActionsTroubleshooting, cont’d Section Replacement Parts Replacement Parts ListSection Technical Data BEFORE CLEANABILITY AFTER CLEANABILITYSAVE THESE INSTRUCTIONS QUAD D.E. CARTRIDGE STYLE FILTER HEAD LOSS COMPARISONQuadD.E P/N 178658 Rev. A 12/9/05