Pentair D.E. Cartridge Style Filter Troubleshooting, cont’d, Problems and Corrective Actions

Page 20
Troubleshooting, cont’d.

14

Troubleshooting, cont’d.

Problems and Corrective Actions

Problem

CorrectiveAction

 

 

 

 

 

PRESSURE DROPS ON GAUGE

 

a. If pressure drops on gauge, shut off power to

 

 

 

pump and turn motor shaft with your fingers.

 

 

 

If it turns freely then the pump must be

 

 

 

disassembled and the impeller checked to see

 

 

 

if it is clogged. If it is not frozen or clogged then

 

 

 

there is an obstruction in the line between the

 

 

 

pool and the pump.

 

 

 

PRESSURE REMAINS HIGH

 

a. If pressure remains high after backwash -

AFTER BACKWASH

 

 

backwash filter again. If still high, treat for

 

 

 

conditions covered by LIMING-UP above.

 

 

 

 

MAINTAIN YOUR PRESSURE GAUGE

The pressure gauge is an important part of the

a.

Check the operation of your pressure gauge

IN GOOD WORKING ORDER

filter system. It is your primary indicator of how

 

in the following manner:

 

the system is operating.

 

(1) The pressure gauge should go to zero (0)

 

 

 

 

 

 

when the system is turned off and pressure

 

 

 

is relieved.

 

 

 

(2) The pressure gauge should indicate pressure

 

 

 

when the system is operating.

 

 

 

(3) The pressure gauge should be readable and

 

 

 

not damaged in any way.

 

 

 

(4) Replace the pressure gauge if it is not

 

 

 

meeting the requirements of items

 

 

 

(1) through (3) of this section.

 

 

 

 

DIATOMITE IS CONTINUOUSLY

 

a.

Inspect the elements for any tears or holes.

ENTERING THE POOL

 

b. Inspect the internal air bleed sock for tears

 

 

 

 

 

and proper installation.

 

 

c.

Inspect the elements and make sure the elements

 

 

 

are positioned vertically and properly seated

 

 

 

between the upper manifold and lower manifold.

 

 

 

 

Quad D.E.™ Filter Installation and User’s Guide

Image 20
Contents D.E. Cartridge Style Filter Installation and Users GuideIMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS Quad D.ECustomer Service Web siteTable of Contents Quad D.E. Filter Installation and User’s GuideIMPORTANT SAFETY PRECAUTIONS Consumer Information and SafetyImportant Notice WARNING - THIS FILTER OPERATES UNDER HIGH PRESSUREIMPORTANT SAFETY PRECAUTIONS continued WARNING - Risk of electrical shock or electrocutionGeneral Installation Information Section Introduction Quad D.E. Cartridge Style Filter OverviewThe crystal clarity of D.E. with cartridge convenience The highest water clarity with the lowest amount of fussGeneral Features Additional FeaturesSection Installation Installing the Quad D.E. FilterGeneral Information, cont.’d WARNING - THIS FILTER OPERATES UNDER HIGH PRESSURESection Filter Operation General Filter InformationClamp Installation Section System Restart Instructions System Restart InstructionsPreparing Diatomite Coating the Filter Elements with Diatomaceous EarthSection Maintenance Cleaning the Quad D.E. Filter ManuallyCleaning your Filter using a System with a Separation Tank Replacing Filter Cartridge Style ElementsCleaning your Filter using a System with a Separation Tank, cont’d Cleaning Filter ElementsCleaning the Internal Air Bleed Tube Cleaning the High Flow Manual Air Relief ValveSection Troubleshooting Problems and Corrective ActionsTroubleshooting, cont’d Section Replacement Parts Replacement Parts ListSection Technical Data BEFORE CLEANABILITY AFTER CLEANABILITYSAVE THESE INSTRUCTIONS QUAD D.E. CARTRIDGE STYLE FILTER HEAD LOSS COMPARISONQuadD.E P/N 178658 Rev. A 12/9/05