Fluke 124, 123 user manual Limited Warranty & Limitation of Liability

Page 2

LIMITED WARRANTY & LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is three years for the Test Tool and one year for its accessories. The warranty period begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke's opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption.

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country.

Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.

To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or abnormal condition of operation or handling, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

Fluke Corporation, P.O. Box 9090, Everett, WA 98206-9090 USA, or

Fluke Industrial B.V., P.O. Box 90, 7600 AB, Almelo, The Netherlands

Image 2
Contents Fluke 123/124 Limited Warranty & Limitation of Liability Service Centers Table of Contents Maintaining the Test Tool Tips and TroubleshootingFluke 123/124 Iii Statement of Conformity Declaration of ConformityManufacturer Sample testsUnpacking the Test Tool Kit Description Fluke Fluke 123/S Fluke 124/SScopeMeter Test Tool Kit Safely Using the Test Tool Safely Using the Test Tool Max. Floating Voltage If Safety Features are ImpairedSpecified Powering the Test Tool Goal of this ChapterResetting the Test Tool Screen After ResetChanging Backlight Reading the Screen Screen AreasMaking Selections in a Menu Basic NavigationInput B Looking at the Measurement ConnectionsInput a Displaying an Unknown Signal with Connect-and View Screen After an Auto SetMeasurement Setup Making MeasurementsHz and Vpp as Main Readings Touch Hold OFF appears on Freezing the ScreenHolding a Stable Reading Making Relative Measurements Making a Relative MeasurementChanging the Time Base Selecting Auto/Manual RangesChanging the Graphic Representation on the Screen Changing the AmplitudeOn the screen Positioning the Waveform on the ScreenObserve that the trigger identifier moves horizontally Smoothing the Waveform 11. Smoothing the WaveformDisplaying the Envelope of a Waveform 12. Displaying the Envelope of a WaveformTrendPlotting a Waveform Starting a TrendPlot functionTurning Off the TrendPlot Display Acquiring the WaveformChanging the TrendPlot Reading Making a Single Acquisition14. Making a Single Acquisition Recording Slow Signals over a Long Period Time 15. Recording Waveforms over Longer Period of TimeSelecting AC-Coupling Reversing the Polarity of the Displayed WaveformSetting Trigger Level and Slope Triggering on a WaveformSelecting the Trigger Parameters Isolated Triggering Triggering on Video Signals 17. Isolated Triggering18. Measuring Video Signals Triggering on a Specific Video Line Saving and Recalling a Setup and a Screen Saving Screens with Belonging SetupsRecalling Screens and Setups Deleting Screens and Associated Setups Using Horizontal Cursors on a Waveform Making Cursor MeasurementsUsing Vertical Cursors on a Waveform Highlight the left cursorMaking Rise Time Measurements 21. Risetime Measurement with CursorsUsing the 101 Probe for High Frequency Measurements Probe AttenuationUsing a Printer Probe Adjustment22. Connecting a Serial Printer Using FlukeView Software Using The Test Tool Using FlukeView Software24. Connecting a Computer Storing the Test Tool Cleaning the Test ToolAbout this Chapter Charging the Rechargeable Battery Pack Charging the Battery PackKeeping Batteries in Optimal Condition Replacing and Disposing of the Rechargeable Battery Pack Replacing the Battery PackUsing and Adjusting 101 Scope Probes Adjusting Scope ProbesFluke 123/124 Calibrating the Test Tool Parts and AccessoriesStandard Accessories Ordering Code Maintaining the Test Tool Optional Accessories SW90WUsing the Tilt Stand Using the Tilt StandChanging the Information Language Changing the Display ContrastChanging Date and Time Saving Battery Life Setting the Power Down TimerChanging the Auto Set Options Potential Using Proper GroundingAll connections to COM are at the same Solving Printing and Other Communication Errors Battery Testing of Fluke AccessoriesIntroduction Performance CharacteristicsSafety Characteristics Environmental DataFrequency Response Dual Input OscilloscopeVertical Rise Time Input ImpedanceHorizontal TriggerAuto Set Advanced Scope FunctionsDisplay Modes Dual Input Meter Input a and Input BPulse Width Pulse PhaseDuty Cycle Duty Decibel dBDiode Ohm ΩContinuity Capacitance CAPCursor readout Fluke Advanced Meter FunctionsDisplay PowerMiscellaneous MemorySafety EnvironmentalBB120 and STL120 Voltage ProbeDisturbance less than 10% of full scale = 3 V/m = 10 V/m VDC, VAC, VAC+DC Index Fluke 123/124 Index Temperature, Environmental

124, 123 specifications

The Fluke 123 and 124 are part of Fluke's innovative range of handheld oscilloscopes designed for electrical and industrial maintenance professionals. These devices combine oscilloscopes with digital multimeter capabilities, making them invaluable tools for troubleshooting and maintenance tasks.

One of the standout features of the Fluke 123 and 124 is their ability to perform real-time waveforms and measurements. Equipped with a 2.5-inch color display, these oscilloscopes provide clear and detailed visualizations of electrical signals. The Fluke 123 offers a bandwidth of 20 MHz, while the Fluke 124 takes it a step further with a bandwidth of 40 MHz, making them versatile tools for various electrical applications.

Both models feature a unique "VPE" (Voltage, Period, and Edge) measurement capability, allowing users to capture electrical signals with precision. This feature is particularly useful in identifying signal distortions and voltage fluctuations, which can lead to equipment failures. Additionally, these devices come with various trigger functions, enabling users to analyze intermittent faults and complex signal behaviors effectively.

Another important characteristic of the Fluke 123 and 124 is their robust design. Built to withstand harsh working environments, they boast an IP51 rating for protection against dust and moisture. The ergonomic design ensures comfort during prolonged use, while the easy-to-navigate interface simplifies its operation.

In terms of battery life, both models are equipped with long-lasting rechargeable batteries, ensuring that users can operate them for extended periods without interruption. Furthermore, they offer storage capabilities for waveform captures, which can be later analyzed or shared with colleagues, enhancing collaboration during troubleshooting efforts.

The Fluke 124 also includes advanced features such as a built-in recording function, allowing users to log measurements over time. This is especially useful for monitoring electrical parameters in industrial processes and systems. Moreover, both models support various probes, giving users the flexibility to tackle different measurement scenarios.

In conclusion, the Fluke 123 and 124 are essential tools for professionals in the electrical and industrial sectors. Their combination of oscilloscope and multimeter functionality, robust design, and advanced measurement capabilities make them ideal for effectively diagnosing and troubleshooting a wide range of electrical issues. Whether it’s for routine maintenance or complex troubleshooting, these devices provide the accuracy and reliability necessary for today's demanding environments.