Meade Telescopes instruction manual

Page 10

5. Bring the star's image slowly in and out of focus until you see several disks sur- rounding the star's center. If steps 1 through 3 were done correctly, you will see con- centric (centered with respect to each other) circles (1, Fig. F).

An improperly collimated instrument will reveal oblong or elongated circles ( ). Adjust the 3 collimating screws on the primary mirror housing until the circles2,areFigcon.F - centric on either side of the focus.

In summary, the adjustment screws on the plastic diagonal mirror housing change the tilt of the secondary mirror so that it is correctly centered in the focuser drawtube, and so that the primary mirror appears centered when looking into the focuser.

The 3 collimating knobs on the primary mirror change the tilt of the primary mirror so that it reflects the light directly up the center of the drawtube.

bc

Fig. F: Correct (1) and incorrect (2) collimation as viewed during a star test.

10

Looking at or near the Sun will cause irreversable damage to your eye. Do not point

 

 

this telescope at or near the Sun. Do not look through the telescope as it is moving.

Image 10 Contents
10, 12, 16 LightBridge Truss Tube Dobsonian Telescopes Page Contents 1% B Assembly Assemble the Base Assemble the Tube Insert Eyepiece and Attach RED DOT Finder Page D e f g Page Deluxe red dot finder Power = 1219mm ÷ 26mm = 47mm ObservingPage Page Page To the optics Specifications Total Assembled telescope wt Deluxe Model Coating technology. Series 4000 Nebular Filters Appendix a Altitude Adjustment Knob Page Page Meade Limited Warranty