Meade LX200 Toc 2. N/S Switch, Toc 3. Ammeter, Toc 4. DEC Motor Connector, Toc 5. CCD Connector

Page 34
CCD Connector Pin LX200 Assignment
#1#Normally Closed
#2West
#3North
#4Ground
#5South
#6East

Meade Instruments Corporation - Meade LX200 Instruction Manuals

Display reads 'Meade LX200', then the version of the software is indicated briefly before defaulting to the TELESCOPE/ OBJECT LIBRARY. Within 15 seconds, the planetary orbital calculations with their corresponding apparent sizes and magnitudes, and current stellar precession calculations are made. Every computer function is checked, and the LX200 diagnostics is complete.

[ toc ] 2. N/S Switch

The recessed N/S Switch (8, Fig. 7) converts the LX200 for operation in the Northern or Southern hemisphere, making the drive reverse its' tracking direction. Before power up, the appropriate N or S switch position should be made, as the LX200 will not recognize a change made on the N/S switch afterwards. Use a pen or small tool to slide the switch appropriately. Be sure before you travel across the equator, that you are setting the proper + or - latitude SITE entry for your final destination.

[ toc ] 3. Ammeter

The Ammeter display (1, Fig. 7) is a series of vertical red LED bars. Each bar that is fully lit represents 0.1 ampere (100 milli-amperes) of current draw. The LED Ammeter represents its' lowest value on the extreme left of the scale. During normal tracking speeds, the Ammeter will show about four fully lit LED bars and at times a fifth that is partially lit, indicating about 400 to 450 milliamps or 0.4 to 0.45 amps of current draw (when a slew in initiated, the ammeter will peg the scale momentarily showing the inertia load, this effect is entirely normal). The current draw information can be useful if you are trying to calculate how much battery life you will have during an observing run. As an example, if the ammeter has four bars lit, indicating 0.4 amps and you are using a 12 amp hour battery, then to know the approximate number of hours of life the battery would yield, you would divide 12 by 0.4 indicating a battery life of 30 hours.

[ toc ] 4. DEC Motor Connector

The DEC Motor Port (11, Fig. 7) is an 8 pin phone jack connector socket, designed to accept standard 8 pin phone jack coil cords. One end of the supplied coil cord plugs in to the Power Panel and the other plugs into the DEC MOTOR socket in the right fork arm to power the declination motor.

[ toc ] 5. CCD Connector

The CCD Port (10, Fig. 7) allows direct interface from popular aftermarket CCD autoguiding/imaging cameras with their compatible connecting cables to accomplish autoguiding for non-attended astrophotography. The CCD cameras effectively watch a star and detect slight movements. When star movements are detected, signals from the CCD electronics make drive corrections in the LX200, to bring the star to a home position.

Most CCD autoguiding/imaging cameras are supplied with a cable which is compatible with the LX200 port. If your CCD unit does not have a cable, one can be obtained from the

CCD manufacturer, or you can make your own cable using the following table of information.

[ toc ] 6. Power 12vDC Connector

The Power 12v DC connector (9, Fig. 7) is designed to accept either the AC Converter that is supplied as standard equipment with the LX200 or the DC Power Cord that is available as optional equipment. The acceptable voltage range (under load) is from 12 to 18 volts.

[ toc ] 7. Keypad Connector

The Keypad connector (6, Fig. 7) is a 4 pin phone jack connector socket, designed to accept standard 4 pin phone jack coil cords. One end of the supplied coil cord plugs into the Keypad port, the other end plugs into

http://www.meade.com/manuals/lx200/f.html (2 of 4) [7/29/2002 7:27:57 AM]

Image 34
Contents Meade Instruments Corporation LX200 Keypad Hand Controller Magnification and Field of View Appendix B Equatorial Use Related TopicsIntroducing the Meade LX200 Important NoteToc e. Keypad and Power Panel Functions Toc 1. What Is the LX200? An OverviewToc c. Altazimuth Mode Operation Toc a. Heavy-Duty Mounts with 9-speed Dual-Axis ElectronicsToc c Model LX200 Toc a Model LX200Toc b Model LX200 Toc d Model LX200Page Toc 1. What You Should Have Unpacking and InspectionWe strongly recommend that you keep your original packing Toc 2. Please Look Everything OverToc 4. Caution All LX200 Owners Keypad Version Number Telescope Assembly Toc 1. The Field Tripod 7, 8, 10 and 12 LX200 ModelsPrecautionary Notes Page Toc 2. Mounting the Viewfinder 7, 8, 10, and 12 LX200 Models Toc a. Attaching the Viewfinder Toc b. Focusing the ViewfinderToc c. Collimating the Viewfinder Toc 5 Tube Swing-Through Limit Toc 4. Checking the Collimation of the OpticsToc 6 Tube Swing-Through Limit Toc 7. Maksutov Fan Toc 1. Using the LX200 Manually Quick StartToc 2. Using the LX200 In Land Motion Speeds Toc 3. Using the LX200 In Altazimuth AltazToc a. Entering Basic Information Toc 1 Latitude and Longitude of the Observing Site Toc 2 Local Time and Date Toc b. Setting Up the Telescope Page Toc c. Using the Telescope Toc 1 The Mode Key Toc 2 Library Object Keys Toc 3 Daytime SlewingNext LX200 Keypad Hand Controller Toc 3. GO to Key Toc 2. Mode KeyToc 1. Enter Key Toc 4. Direction KeysToc 8. MAP Key Toc 6. RET KeyToc 7. Focus Key Toc 9. Object Keys M, STAR, and CngcPage LX200 Power Panel Toc 1. ON/ OFF SwitchToc 5. CCD Connector Toc 2. N/S SwitchToc 4. DEC Motor Connector Toc 6. Power 12vDC ConnectorToc 10. RS-232 Connector Toc 8. Reticle ConnectorToc 9. Focuser Connector Toc 11. Aux ConnectorPage Toc a. Telescope Menu File Mode FunctionsToc 1. Mode One TELESCOPE/ Object Library Toc 1 SiteToc a -Star with Known Site Toc 2 AlignToc a Altaz Toc b -Star at Known SiteToc c. Unknown Site Toc d. Which Alignment Method To Use?Page Toc b Polar Toc c Refined Polar AlignmentToc e Land Toc 3 SmartToc 6 Reverse NS Toc 4 12/24 HRToc 5 Help Toc 7 Reverse EWToc 9 HP High-Precision Pointing Toc a LX200 Pointing AccuracyToc 11 DEC. Backlash Compensation Toc b. Object Library Menu File Toc 2 Start FindToc a Type Gpdco Toc 3 FieldToc 4 Parameters Object Sysmbol LegendToc c Higher Quality Symbol LegendToc b Better Toc d LargerToc f Brighter Toc 2. Mode Two COORDINATES/ GO toToc e Smaller Toc g FainterToc b. GO to Menu Option Toc 3. Mode Three CLOCK/ CalendarToc c. Slew To Altaz Coordinates Drive Rate Settings Toc 4. Mode Four TIMER/ Freq a. Timer = Menu OptionToc b. FREQ= Menu File Toc 5. Mode Five Keypad OFF/ Brightness Adjust Magnification and Field of View toc 1. Magnifications Toc 2. Apparent Field and Actual Field O.D., except as notedPage Appendix a Equatorial Wedge Toc 1 Equatorial Wedge For 7 and 8 LX200Equatorial Wedge for 7 and 8 LX200 Telescope Toc a. Azimuth ControlToc b. Deluxe Latitude Adjuster Toc 2. Superwedge For 10 and 12LX200 Mounting Superwedge, b Latitude Range Holes Page Underside of the Drive Base Toc a. Setting Magnetic Declination Toc b. Compass Installation Toc c. Finding True North Page Page Next Page Appendix B Equatorial USE Toc 1. Celestial Coordinates Declination and Right AscensionPage Toc 2. Lining Up with the Celestial Pole Toc 3. Precise Polar Alignment Page Next Toc 1. Alignment Stars Appendix C LX200 Alignment Star Library and Star ChartsToc LX200 Alignment Star Library Star Charts for Northern Hemisphere Observers Page Next Page Toc 2. The Cngc Catalog VQ Guide Cngc ListingsTags Cngc Types Toc 3. The Star CatalogToc 6. The Planets Toc 4. Select Star by NameToc 5. The M Catalog Object Library Planet Legend Toc 7. Other DatabasesConstellation Codes Related Topics Page Meade Instruments Corporation Page Toc 2. Collimation Alignment of the Optical System Page Defocused Star Images Toc 4. Behind the Power Panel Toc 3. Adjusting the Right Ascension LockToc 5. Factory Servicing and Repairs