Meade LX200 Toc 4. Mode Four TIMER/ Freq a. Timer = Menu Option, Toc b. FREQ= Menu File

Page 51
[ toc ]

Meade Instruments Corporation - Meade LX200 Instruction Manuals

this manual. Be sure to use your local hour setting appropriately in either 12 hour or 24 hour format as predetermined by the 12/24 HOUR TELESCOPE menu file option.

The long-life lithium battery (Panasonic CR2032 3 volt or Duracell DL2032B) is stored behind the Power Panel of the Drive Base. See Appendix E. in this manual for battery replacement information.

[ toc ] 4. Mode Four: TIMER/ FREQ a. TIMER = Menu Option

The TIMER = menu option is for accurately timing different observing or imaging tasks for up to twelve hours long. Counting down to zero, in the hours, minutes, and seconds format, it will give a pleasant beeping tone to notify you that the time is up.

To set the TIMER, move the LCD arrow to TIMER= 00:00:00. Then press and hold the ENTER key to get the double beep tone and the blinking cursor. Enter the number of hours, minutes, and seconds that you require. If you need to correct an error in entry, use the E and W keys to move the blinking cursor and then type in the correct information. After entry, press the ENTER key again and the cursor will eliminate. When you are ready to start your time count-down, press the ENTER key once more. To pause the count-down press ENTER again, and then again to resume.

If you merely want an automatic 12 hour count-down, just press the ENTER key without holding. Then press ENTER to count-down.

[ toc ] b. FREQ= Menu File

FREQ= (Frequency) allows you to adjust the tracking speeds (not slew speeds) of the LX200 digitally in tenths of a hertz from 56.4 Hz to 60.1 Hz, so that you can match virtually every celestial motion in the sky. Some popular drive rate settings are:

Table 7: Drive Rate Settings

FREQUENCY RATE DESCRIPTION

NOTES

 

 

 

Default rate at power up. Gives sidereal

60.1

Hz Q

Sidereal Rate; Quartz setting frequency accuracy to + or - .005%; Best for

 

 

 

most astrophotography.

60.0

Hz

Solar and Planetary rate

Average rate for tracking planets; Actual rates

vary due to retrogrades, oppositions, etc.

 

 

 

57.9

Hz

Lunar rate

Best for tracking the Moon.

Note: If you have trained the Smart Drive in the 60.1 Hz Q setting (see SMART menu file in this section), you will find that Smart Drive will still give periodic error corrections in all of the other frequency settings. There are three menu file options in FREQ=. To see or set the options, move the LCD arrow to FREQ= and press the ENTER key. At power up, the FREQ= default is the 60.1Hz Q setting. The quartz rate is precisely fixed and cannot be altered. To choose a rate other than the quartz setting, press the ENTER key to see

60.1M and then again to see 60.1 M with the up and down LCD arrow. These two menu file options can adjust the tracking speeds. The adjustment techniques are described below:

http://www.meade.com/manuals/lx200/g.html (15 of 16) [7/29/2002 7:28:04 AM]

Image 51
Contents Meade Instruments Corporation LX200 Keypad Hand Controller Magnification and Field of View Related Topics Appendix B Equatorial UseImportant Note Introducing the Meade LX200Toc a. Heavy-Duty Mounts with 9-speed Dual-Axis Electronics Toc 1. What Is the LX200? An OverviewToc c. Altazimuth Mode Operation Toc e. Keypad and Power Panel FunctionsToc d Model LX200 Toc a Model LX200Toc b Model LX200 Toc c Model LX200Page Toc 2. Please Look Everything Over Unpacking and InspectionWe strongly recommend that you keep your original packing Toc 1. What You Should HaveToc 4. Caution All LX200 Owners Keypad Version Number Toc 1. The Field Tripod 7, 8, 10 and 12 LX200 Models Telescope AssemblyPrecautionary Notes Page Toc 2. Mounting the Viewfinder 7, 8, 10, and 12 LX200 Models Toc b. Focusing the Viewfinder Toc a. Attaching the ViewfinderToc c. Collimating the Viewfinder Toc 4. Checking the Collimation of the Optics Toc 5 Tube Swing-Through LimitToc 6 Tube Swing-Through Limit Toc 7. Maksutov Fan Quick Start Toc 1. Using the LX200 ManuallyToc 2. Using the LX200 In Land Toc 3. Using the LX200 In Altazimuth Altaz Motion SpeedsToc a. Entering Basic Information Toc 1 Latitude and Longitude of the Observing Site Toc 2 Local Time and Date Toc b. Setting Up the Telescope Page Toc c. Using the Telescope Toc 1 The Mode Key Toc 3 Daytime Slewing Toc 2 Library Object KeysNext LX200 Keypad Hand Controller Toc 4. Direction Keys Toc 2. Mode KeyToc 1. Enter Key Toc 3. GO to KeyToc 9. Object Keys M, STAR, and Cngc Toc 6. RET KeyToc 7. Focus Key Toc 8. MAP KeyPage Toc 1. ON/ OFF Switch LX200 Power PanelToc 6. Power 12vDC Connector Toc 2. N/S SwitchToc 4. DEC Motor Connector Toc 5. CCD ConnectorToc 11. Aux Connector Toc 8. Reticle ConnectorToc 9. Focuser Connector Toc 10. RS-232 ConnectorPage Toc 1 Site Mode FunctionsToc 1. Mode One TELESCOPE/ Object Library Toc a. Telescope Menu FileToc b -Star at Known Site Toc 2 AlignToc a Altaz Toc a -Star with Known SiteToc d. Which Alignment Method To Use? Toc c. Unknown SitePage Toc c Refined Polar Alignment Toc b PolarToc 3 Smart Toc e LandToc 7 Reverse EW Toc 4 12/24 HRToc 5 Help Toc 6 Reverse NSToc a LX200 Pointing Accuracy Toc 9 HP High-Precision PointingToc 11 DEC. Backlash Compensation Toc 2 Start Find Toc b. Object Library Menu FileObject Sysmbol Legend Toc 3 FieldToc 4 Parameters Toc a Type GpdcoToc d Larger Quality Symbol LegendToc b Better Toc c HigherToc g Fainter Toc 2. Mode Two COORDINATES/ GO toToc e Smaller Toc f BrighterToc 3. Mode Three CLOCK/ Calendar Toc b. GO to Menu OptionToc c. Slew To Altaz Coordinates Toc 4. Mode Four TIMER/ Freq a. Timer = Menu Option Drive Rate SettingsToc b. FREQ= Menu File Toc 5. Mode Five Keypad OFF/ Brightness Adjust Magnification and Field of View toc 1. Magnifications O.D., except as noted Toc 2. Apparent Field and Actual FieldPage Toc 1 Equatorial Wedge For 7 and 8 LX200 Appendix a Equatorial WedgeToc a. Azimuth Control Equatorial Wedge for 7 and 8 LX200 TelescopeToc b. Deluxe Latitude Adjuster Toc 2. Superwedge For 10 and 12LX200 Mounting Superwedge, b Latitude Range Holes Page Underside of the Drive Base Toc a. Setting Magnetic Declination Toc b. Compass Installation Toc c. Finding True North Page Page Next Page Toc 1. Celestial Coordinates Declination and Right Ascension Appendix B Equatorial USEPage Toc 2. Lining Up with the Celestial Pole Toc 3. Precise Polar Alignment Page Next Appendix C LX200 Alignment Star Library and Star Charts Toc 1. Alignment StarsToc LX200 Alignment Star Library Star Charts for Northern Hemisphere Observers Page Next Page Toc 2. The Cngc Catalog Cngc Listings VQ GuideCngc Types Toc 3. The Star Catalog TagsObject Library Planet Legend Toc 7. Other Databases Toc 4. Select Star by NameToc 5. The M Catalog Toc 6. The PlanetsConstellation Codes Related Topics Page Meade Instruments Corporation Page Toc 2. Collimation Alignment of the Optical System Page Defocused Star Images Toc 3. Adjusting the Right Ascension Lock Toc 4. Behind the Power PanelToc 5. Factory Servicing and Repairs