Orion 9791 instruction manual Installing the Finder Scope and Eyepieces

Page 18

Encoder retaining knob

Aluminum shaft of altitude encoder assembly

 

Altitude side

 

bearing

Altitude

Right panel

retaining

 

knob

 

spacer

 

Figure 30. The shaft of the other knob (the retaining knob) goes through the hollow aluminum shaft of the altitude encoder and threads into the other altitude side bearing on the tube. Make sure to put the white nylon spacer on the shaft before threading it in.

against the CorrecTension pads on the interior surface of the left panel.

3.On the other (retaining) knob, slide the altitude retain- ing knob spacer onto the threaded shaft. Then push the shaft through the altitude encoder’s aluminum shaft (now protruding from the right side panel) and into the optical tube’s other altitude bearing (Figure 30). You can move the altitude encoder up and down a bit with the knob in order to have the knob’s shaft line up with the threaded hole in the tube’s altitude bearing. Make sure this knob is always fully tightened, or else the IntelliScope’s altitude encoder will not work properly.

Installing the Finder Scope and Eyepieces

These accessories can be found in the optical tube assembly box.

1.To install the finder scope into its bracket, first remove the O-ring from the bracket and place it over the body of the

Tensioner

Black nylon thumb screws

Figure 31. Pull back on the tensioner and slide the finder scope into its bracket until the O-ring is seated in the recess in the front of the bracket.

 

Thumb screw

 

 

Dovetail

 

Foot of

base

 

 

 

finder

 

 

 

 

 

scope

 

 

 

 

bracket

 

 

 

 

Figure 32. The foot of the finder scope bracket goes into the dovetail base and is secured with the thumb screw.

finder scope until it seats into the groove in the middle of the finder. Unthread the black nylon alignment screws on the bracket until the screw ends are flush with the inside diameter of the bracket. Slide the eyepiece end (narrow

18

Image 18
Contents Orion SkyQuest IntelliScope Truss Tube Dobsonian #9791SkyQuest XX14i IntelliScope Truss Tube Dobsonian Table Contents UnpackingNavigation Knob Counterweights Parts List Box #1A IntelliScope Object Locator Kit refer to FigureBox #2 Primary Mirror and Cell refer to Figure Box #3 Dobsonian Base refer to Qty. DescriptionTop baseplate Assembly Assembly of the Dobsonian BaseBox #4 Truss poles refer to Figure Exploded view of the XX14i base Azimuth encoder board Brass azimuth Bushing Nylon spacer Assembly of the Optical Tube Page Ring Connector Truss poles Mounting the Optical Tube on Dobsonian Base Installing the Finder Scope and Eyepieces Adapter Thumb screws Coarse Focus Primary Mirror Center Mark Aligning Collimating the Optical SystemCollimation Cap Preparing the Telescope for CollimatingAdjusting the Secondary Mirror’s Axial Position Adjusting the Secondary Mirror’s Radial PositionAligning the Secondary Mirror Star-Testing the Telescope Adjusting the Secondary Mirror’s Rotational PositionAdjusting the Secondary Mirror’s Tilt Aligning the Primary MirrorUsing Your Telescope Setting the Altitude TensionAltitude and Azimuth Motion Focusing the Telescope Viewing with EyeglassesAligning the Finder Scope Magnification Focusing the Finder ScopeAiming/Pointing the Telescope 1650mmTube Balance Disassembly of the Optical TubeDisassembly of the Base Disassembling the Telescope for TransportAstronomical Observing IntelliScope Computerized Object LocatorSelecting an Observing Site Use of the Optional Light ShroudSeeing and Transparency Cooling the Telescope Let Your Eyes Dark-AdaptEyepiece Selection Astronomical Objects MoonCare and Maintenance Cleaning Eyepiece LensesCleaning Mirrors Page Accessories SpecificationsOptical Tube Assembly OTA MountOne-Year Limited Warranty