Celestron C6-RGT manual Adjusting the Mount in Azimuth, Powering the Telescope

Page 14
Figure 2-15

latitude screw, first use the rear screw to raise the mount head all the way up. Then remove the front latitude screw completely. Now you should be able to manually move the mount head all the way to its lowest latitude. Now, using only the rear screw, raise the mount to your desired latitude.

Adjusting the Mount in Azimuth

For rough adjustments in azimuth, simply pick up the telescope and tripod and move it. For fine adjustments in azimuth:

1.Turn the azimuth adjustment knobs located on either side of the azimuth housing (see Fig 2-14). While standing behind the telescope, the knobs are on the front of the mount.

Turning the right adjustment knob clockwise moves the mount toward the right.

Turning the left adjustment knob clockwise moves the mount to the left.

Both screws push off of the peg on the tripod head, which means you may have to loosen one screw while tightening the other. The screw that holds the equatorial mount to the tripod may have to be loosened slightly.

Keep in mind that adjusting the mount is done during the polar alignment process only. Once polar aligned, the mount must NOT be moved. Pointing the telescope is done by moving the mount in right ascension and declination, as described earlier in this manual.

Attaching the Declination Cable (For GT Models Only)

The Advanced Series mount comes with a declination cable that connects from the R.A. motor drive electronic panel to the Dec motor drive. To attach the motor cable:

Locate the Declination cable and plug one end of

 

 

 

 

 

DEC Locking

 

the cable into the port on the electronics panel

 

 

 

 

 

Clamp

 

labeled DEC Port and plug the other end of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable into the port located on the declination

 

 

 

 

 

 

 

 

 

 

motor drive (see Fig 2-15).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R.A. Locking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Powering the Telescope

Clamp

 

 

 

Declination Cable

 

 

 

 

Input Port

The Advanced GT can be powered by the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supplied car battery adapter or optional 12v AC

 

 

 

 

 

 

 

 

 

 

adapter. Use only adapters supplied by Celestron.

 

 

 

 

 

 

 

 

 

 

 

 

 

Declination Cable

 

 

Using any other

adapter

may

damage the

 

 

 

 

 

 

 

 

Output Port

 

 

electronics or cause the telescope not to operate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

properly, and will

void

your

manufacturer's

 

 

12v Power Input

 

 

warranty.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On/Off Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.To power the telescope with the car battery adapter (or 12v AC adapter), simply plug the round post into the 12v

outlet on the electronic panel and plug the other end into your cars cigarette

lighter outlet or portable power supply (see Optional Accessories). Note: to prevent the power cord from being accidentally pulled out, wrap the power cord around the strain relief located below the power switch.

2.Turn on the power to the telescope by flipping the switch, located on the electronics panel, to the "On" position.

14

Image 14
Contents Advanced Series Advanced Series GT Assembly Version Get Alt-Az Goto Alt-Az Hibernate Turn On/Off GPS Page Advanced Series C6-R C8-N ShownAdvanced Series C6-RGT Setting up the Tripod Attaching the Equatorial MountInstalling the Counterweight Bar Attaching the Center Leg BraceInstalling the Counterweight Attaching the Hand Control Holder Advanced GT Models OnlyAttaching the Telescope Tube to the Mount Installing the Finderscope Balancing the Tube in R.A Telescope Tube CompletelyAdjusting the Mount Adjusting the Mount in AltitudeAttaching the Declination Cable For GT Models Only Adjusting the Mount in AzimuthPowering the Telescope Advanced GT Hand Control Hand Control Operation Double StarsAlignment Procedures Startup ProcedureAuto Align Auto Three-Star AlignRe-Alignment Quick-AlignLast Alignment Slewing to an Object Object CatalogSelecting an Object Finding PlanetsDirection Buttons Tour ModeConstellation Tour Rate ButtonSetup Procedures Identify Scope Setup Features Precise GoToObserving Tip Helpful Hint Utility Features Helpful Hint Advanced GT Image Orientation Calculating Magnification FocusingAligning the Finderscope Determining Field of View General Observing HintsCelestial Coordinate System Motion of the Stars Pointing at Polaris Finding the North Celestial Pole Declination Drift Method of Polar Alignment Observing the Planets Observing the MoonLunar Observing Hints Observing the SunSeeing Conditions Solar Observing HintsObserving Deep Sky Objects TransparencyUsing the Lens Cap Aperture Stop Piggyback Short Exposure Prime Focus Photography Reducing Vibration Terrestrial PhotographyMetering Auto Guiding Care and Cleaning of the Optics CollimationCollimated telescope Should appear as a Page Page Page Appendix a Technical Specifications Appendix B Glossary of Terms Page Eclipsing or obscuring the brightness of the star Appendix C Longitudes Latitudes Georgia Minnesota Rhode Island Canada Appendix D RS-232 Connection Additional RS232 Commands Appendix E Maps of Time Zones Page Page Page Page Page Page Page Celestron TWO Year Warranty