REVERSE CHANNEL OUTPUT (OPTIONAL SETUP)

Action

1)Press and hold PROGRAM & TAPSYNC buttons together (2) times to access the channel assignment mode then select the FIXTURE button.

2)Move the SPEED fader until you arrive at the controller channel you wish to alter.

3)Move the FADE TIME fader all the way up until N changes to Y.

If you wish to copy a scanner’s reverse channel assignments to another scanner, continue by following steps 4-10. If you do not wish to do this, press and hold PROGRAM & TAPSYNC buttons

(1) times to exit mode.

Example: Copying Scanner 1 into Scanner 2

4)Press and hold FIXTURE button # 1.

5)While holding button # 1 press FIXTURE button # 2.

6)While holding FIXTURE buttons # 1 and # 2, press and hold MIDI/ADD button.

7)Release FIXTURE button # 1 first before releasing FIXTURE button # 2.

8)Release MIDI/ADD button.

9)All FIXTURE LED indicators will flash to confirm successful copy.

10)Press and hold PROGRAM & TAPSYNC buttons (1) times to exit mode.

Notes

You can permanently reverse the output of any given channel on the controller.

FADE TIME ASSIGN (OPTIONAL SETUP)

You can choose whether the board’s fade time during scene execution is implemented broadly to all output channels or only to the Pan and Tilt movement channels. This is relevant because often you will want gobos and colors to change quickly while not affecting the movement of the light.

Action

1)Turn OFF the controller.

2)Hold the BLACKOUT and TAPSYNC buttons simultaneously.

3)Turn ON the controller.

4)Press the TAPSYNC button to toggle between the two modes. Either all channels

(A) or select channel Pan & Tilt only (P)

5)Press BLACKOUT and TAPSYNC to save settings. All LED’s will blink to confirm.

Notes

Obey™-40 User Manual

10

Revised: 2008-06-13 15:54:24

Image 10
Contents Snapshot Table of Contents Before YOU Begin What is includedSafety Instructions Unpacking InstructionsFeatures IntroductionProduct Overview front Button or Fader FunctionProduct Overview rear panel Common Terms Resetting the System SetupSetting UP the System Operating InstructionsPhysical Fader Assignment Optional Setup ActionReverse Channel Output Optional Setup Fade Time Assign Optional SetupCreate a Scene Entering Program ModeProgramming Edit a SceneDelete ALL Scenes Scene CopyDelete Scene Bank CopyCreate a Chase Chase ProgrammingCopy Bank Into Chase Delete a SCENE/STEP in a Chase Adding a Step to a ChaseDelete a Chase Playback Scenes Auto RUN Chases Playback ChasesManual RUN Chases Music RUN ChasesStore midi setup settings Midi OperationDMX Primer AppendixFixture Linking Troubleshooting Returns ProcedureClaims DMX Dipswitch Quick Reference Chart DMX Address Quick Reference ChartGeneral Troubleshooting Applies toTechnical Specifications Control & Programming
Related manuals
Manual 6 pages 14.6 Kb Manual 10 pages 13.12 Kb Manual 12 pages 33.3 Kb Manual 12 pages 16.52 Kb Manual 32 pages 8.49 Kb Manual 17 pages 54.12 Kb Manual 17 pages 50.34 Kb Manual 21 pages 39.46 Kb Manual 19 pages 53.54 Kb

DMX512 specifications

Chauvet DMX512 is a widely used standard in the lighting industry, particularly in theatrical productions, concerts, and events. This protocol facilitates communication between lighting consoles and various lighting fixtures, streamlining the control of lights in a synchronized manner. Understanding its core features, technologies, and characteristics can significantly enhance the capabilities of any lighting designer or technician.

One of the main features of DMX512 is its ability to control multiple devices from a single controller. This is achieved by using a daisy-chaining method where up to 512 channels can be managed over a single network. Each channel can control various parameters of a lighting fixture, such as intensity, color, and movement. The flexibility of DMX512 allows lighting designers to create intricate shows with seamless transitions and effects.

Another crucial aspect of DMX512 is its robust technology that includes differential signaling. This aids in reducing signal interference and ensures that signals can be transmitted over long distances, making it ideal for large venues. The standard operates at a speed of 250 kbaud, providing reliable and fast communication between devices.

Additionally, DMX512 employs a 3-pin or 5-pin XLR connector, commonly found in both commercial and professional lighting systems. This standardization allows for ease of setup and compatibility with various equipment, enhancing the versatility of different lighting rigs.

One of the defining characteristics of DMX512 is its backward compatibility with older lighting technologies, making it an excellent option for venues transitioning from analog to digital controls. Its widespread acceptance means that users can access a plethora of lighting equipment designed to interact with DMX512, ranging from simple par cans to sophisticated moving head fixtures.

Moreover, DMX512 supports a variety of fixture types, including LED lights, fog machines, and intelligent fixtures. This versatility equips lighting designers with a diverse toolbox for creating dynamic visual presentations that can adapt to the needs of their specific projects.

In summary, Chauvet DMX512 is an essential protocol for any lighting professional, offering a combination of extensive control, reliability, and flexibility. Its compatibility with numerous lighting devices, robust signal transmission capabilities, and widespread usage make it a cornerstone of modern lighting design, ensuring that creators can bring their artistic visions to life efficiently and effectively.