2Server Utilities

Using the BIOS Setup Utility

This section describes the BIOS Setup Utility options, which is used to change server configuration defaults. You can run BIOS Setup with or without an operating system being present. See “Additional Information and Software” for a link to the Intel® S5000 Server Board Family Data Sheet where you will find details about specific BIOS setup screens.

Starting Setup

You can enter and start BIOS Setup under several conditions:

When you turn on the server, after POST completes the memory test.

When you have moved the CMOS jumper on the server board to the "Clear CMOS" position (enabled).

In the two conditions listed above, during the Power On Self Test (POST), you will see this prompt:

Press <F2> to enter SETUP

In a third condition, when CMOS/NVRAM has been corrupted, you will see other prompts but not the <F2> prompt:

Warning: CMOS checksum invalid

Warning: CMOS time and date not set

In this condition, the BIOS will load default values for CMOS and attempt to boot.

If You Cannot Access Setup

If you are not able to access BIOS Setup, you might need to clear the CMOS memory. For instructions on clearing the CMOS, see "Clearing the CMOS".

Setup Menus

Each BIOS Setup menu page contains a number of features. Except for those features that are provided only to display automatically configured information, each feature is associated with a value field that contains user-selectable parameters. These parameters can be changed if the user has adequate security rights. If a value cannot be changed for any reason, the feature's value field is inaccessible.

Image 29
Contents Intel Order Number D36977-002 Intel Server Board S5000VSA User’s GuideDisclaimer Safety Information 重要安全指导 Intel Server Board S5000VSA User’s Guide Intel Server Board S5000VSA User’s Guide Manual Organization About this ManualAdditional Information and Software Product AccessoriesAdditional Information and Software For this information or Use this Document or SoftwareIntel Server Board S5000VSA User’s Guide Intel Server Board S5000VSA User’s Guide Contents Appendix a Getting Help Appendix D Intel Server Issue Report Form Xiv List of Tables Xvi Intel Server Board S5000VSA List of FiguresXviii Intel Server Board S5000VSA Server Board FeaturesFeature Description Server Board FeaturesSata Server Board RAID SupportSAS Server Board EE Ccaa DD BB Z Y Connector and Component LocationsServer Board Connector and Component Locations Jumper Name Jumper Purpose Configuration JumpersLED State Description Back Panel ConnectorsNIC LED Descriptions Processor Hardware RequirementsMemory Memory Sparing and MirroringOptional Hardware Power SupplyHard Disk Drives Intel Local Control PanelStarting Setup Using the Bios Setup UtilityIf You Cannot Access Setup Setup MenusKey to Press Description Setup Menu Key UseRecording the Current Bios Settings Upgrading the BiosPreparing for the Upgrade Obtaining the Upgrade Upgrading the BiosPassword Clear Jumper Clearing the PasswordCmos Clear Jumper Clearing the CmosInstalling and Removing Memory Hardware Installations and UpgradesInstalling DIMMs Before You BeginInstalling Memory Removing DIMMs Installing or Replacing the ProcessorLifting the Socket Handle Installing the ProcessorRemoving the Shipping Cover Installing the Heat Sink Installing the Heat SinksRemoving a Processor Replacing the Backup Battery Replacing the Backup Battery Intel Server Board S5000VSA User’s Guide Canada Europe Appendix a Getting HelpWorld Wide Web Telephone Latin America Asia-Pacific RegionJapan Panama Intel Server Board S5000VSA User’s Guide Product Regulatory Compliance Product Safety ComplianceAppendix B Regulatory and Compliance Information Product Regulatory Compliance Markings Certifications / Registrations / DeclarationsProduct Certification Markings Regulatory Region Marking ComplianceRegulatory Region Marking Compliance Bsmi Marking Class Electromagnetic Compatibility NoticesTaiwan Declaration of Conformity Bsmi Industry Canada ICES-003Europe CE Declaration of Conformity Cnca CCC-China Korean Compliance RRLEnd-of-Life / Product Recycling Restriction of Hazardous Substances RoHS ComplianceResetting the System Appendix C TroubleshootingProblems following Initial System Installation Resetting the SystemFirst Steps Checklist Hardware Diagnostic TestingConfirming Loading of the Operating System Specific Problems and Corrective ActionsVerifying Proper Operation of Key System Lights No Characters Appear on Screen Power Light Does Not LightSystem Cooling Fans Do Not Rotate Properly Characters Are Distorted or IncorrectServer hangs when the drivers are loaded Problems with NetworkCD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light Cannot Connect to a ServerProblems with Newly Installed Application Software System Boots when Installing PCI CardDiagnostics pass but the connection fails Add-in adapter stopped working without apparent causeHard Drives are not Recognized LED Information Bootable CD-ROM Disk Is Not DetectedLED Information LED Name Function Location LED ColorNumber Reason for Beeps and Action to Take Bios Post Beep CodesPost Error Beep Codes Board / Chassis Information Appendix D Intel Server Issue Report FormOperating System Information Dimm ConfigurationAdd-in Card, Peripheral, Video, NIC Peripheral Description DriverManagement Information Hard Drive InformationControl Panel Information Base Revision AddressComplete Problem Description
Related manuals
Manual 13 pages 57.44 Kb

S5000VSA specifications

The Intel S5000VSA is a server motherboard that has been tailored to meet the needs of businesses requiring a reliable and scalable infrastructure. Designed for Intel's 5000 series of chipsets, this motherboard is notable for its standards in performance, flexibility, and management capabilities.

One of the standout features of the Intel S5000VSA is its support for dual Intel Xeon processors. The flexibility to utilize various Xeon chips allows organizations to select the optimal processing power for their specific workloads, whether that be database management, virtualization, or heavy computation tasks. This capability is essential for providing the high levels of performance and responsiveness businesses demand in their server environments.

The motherboard supports up to 32GB of memory using DDR2 technology, with eight DIMM slots available for expansion. This memory capacity allows for significant multitasking and resource management, essential in data-heavy server applications. The board supports both ECC (Error-Correcting Code) and non-ECC memory, offering organizations options depending on their fault tolerance needs.

In terms of connectivity, the S5000VSA comes equipped with multiple PCI Express slots, providing ample options for expandability with various I/O cards or additional network interfaces. This is particularly important as businesses grow and require additional capabilities or higher performance networking solutions.

The Intel S5000VSA is also noted for its advanced management features. Integrated Remote Management capabilities enable IT administrators to monitor and manage the system from afar, enhancing both uptime and ease of maintenance. Support for Intel’s Active Management Technology (AMT) allows for greater control over the server and improves security by enabling remote management regardless of the operating system state.

Another important aspect of the S5000VSA is its built-in RAID controller that supports several RAID levels. This feature enhances data reliability and performance, allowing users to configure their storage systems according to their needs, whether they prioritize speed or redundancy.

In summary, the Intel S5000VSA is a robust server motherboard designed with scalability, performance, and management in mind. It supports dual Xeon processors, offers extensive memory options, and provides essential features such as RAID support and remote management. This makes it a suitable choice for data centers and enterprises looking for a competitive edge through advanced technology.